The Enhancement of 3 MHz Ultrasonic Echo Signal for Conversion Curve Development for Acoustic Impedance Estimation by Using Wavelet Transform Prastika, Edo Bagus; Gunawan, Agus Indra; Bayu Dewantara, Bima Sena; Hozumi, Naohiro; Prianto, Chandra Edy
EMITTER International Journal of Engineering Technology Vol 6, No 1 (2018)
Publisher : Politeknik Elektronika Negeri Surabaya (PENS)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24003/emitter.v6i1.245

Abstract

Ultrasonic technology has already been used for many applications. Most of them are mainly used for object measurement. Some techniques have been widely applied to particular measurement by utilizing a very specific component. In this research, the previous technique to develop a conversion curve to obtain the acoustic impedance of the target is adopted. Then, we propose a 3 MHz concave shaped ultrasonic transducer for measuring liquids and a confirmation is needed to confirm if the system used is correct. Therefore, several saline solutions which property has been known are used. A low voltage of 10 Volt pulse is used to trigger the transducer. The ultrasonic wave is then transmitted through the multilayered mediums, which is pure water, clear acrylic, and the target. The echo from the interface between the acrylic and the target is then received by the same transducer. Some parameters such as peak and RMS are used to develop the conversion curve. A peak detection and comparison between the original echo and the processed one by using Wavelet transform (UWT and DWT) is then performed. Some analysis of the echo signal by using multiresolution and time-frequency analysis is also proposed. The result obtained from the measurement is then compared to that from the theoretical calculation. Based on the result, in terms of developing the calibration graph, only the RMS value (UWT) which has the closest trend to the result of the calculation, with the mean percentage error of 0.65512%, which is the smallest value among all parameters.
Design and Implementation of Embedded Water Quality Control and Monitoring System for Indoor Shrimp Cultivation Natan, Oskar; Gunawan, Agus Indra; Dewantara, Bima Sena Bayu
EMITTER International Journal of Engineering Technology Vol 7, No 1 (2019)
Publisher : Politeknik Elektronika Negeri Surabaya (PENS)

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (724.62 KB) | DOI: 10.24003/emitter.v7i1.344

Abstract

Maintaining the water quality of a pond is one of the main issues on aquaculture management. Water quality represents the condition of a pond based on several water parameters such as dissolved oxygen (DO), temperature, pH, and salinity. All of these parameters need to be strictly supervised since it affects the life-sustainability of cultivated organisms. However, DO is said to be the main parameter since it affects the growth and survival rate of the shrimp. Therefore, a water quality control and monitoring system is needed to maintain water parameters at acceptable value. The system is developed on a mini-PC and microcontroller which are integrated with several sensors and actuator forming an embedded system. Then, this system is used to collect water quality data that is consisting of several water parameters and control the DO as the main parameter. In accordance with the stability needs against the sensitive environment, a fuzzy logic-based controller is developed to maintain the DO rate in the water. This system is also equipped with SIM800 module to notice the farmer by SMS, built-in wifi module for web-based data logging, and improved with Android-based graphical user interface (GUI) to perform user-friendly monitoring. From the experiment results, a fuzzy controller that is attached to the system can control the DO at the acceptable value of 6 ppm. The controller is said to have high robustness since its deviation for long-time use is only 0.12 ppm. Another test shows that the controller is able to overcome the given disturbance and easily adapt when the DO’s set point is changed.  Finally, the system is able to collect and store the data into cloud storage periodically and show the data on a website.