Claim Missing Document
Check
Articles

Found 2 Documents
Search

MODIFIKASI ELEKTRODA KARBON DENGAN NIFEOX SEBAGAI PLATFORM SENSOR ELEKTROKIMIA UNTUK PENDETEKSIAN DOPAMIN Yasin, Anggita Putri; Susila, Anggara Budi; Hermawan, Angga
PROSIDING SEMINAR NASIONAL FISIKA (E-JOURNAL) Vol. 12 (2024): PROSIDING SEMINAR NASIONAL FISIKA (E-JOURNAL) SNF2023
Publisher : Program Studi Pendidikan Fisika dan Program Studi Fisika Universitas Negeri Jakarta, LPPM Universitas Negeri Jakarta, HFI Jakarta, HFI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21009/03.1201.FA36

Abstract

Abstrak Pada penelitian ini, telah dilakukan fabrikasi dan karakterisasi elektroda sensor elektrokimia yang dilakukan untuk mendeteksi dopamin, salah satu biomarker penyakit parkinson, berbasis NiFeOx menggunakan metode lelehan garam. Penelitian ini bertujuan untuk melihat pengaruh penggunaan lelehan garam KOH terhadap serta performa sensor elektrokimia dari NiFeOx. Glassy carbon electrode (GCE) yang telah dimodifikasi dengan NiFeOx (GCE@NiFeOx) dikarakterisasi menggunakan teknik voltametri siklik untuk mendeteksi keberadaan dopamin. Pengukuran dilakukan dengan laju pemindaian 20-300 mV/detik padca konsentrasi dopamin 1 mmol didalam elektrolit 0.1 M PBS (Phosphate Buffered Saline) dengan rentang potensial -0.1- 0.4 V vs Ag/AgCl. Hasil penelitian secara voltametri siklik menunjukan bahwa sampel NiFeOx sensitive terhadap molekul dopamin ditandai dengan arus puncak oksidasi sebesar 12 µA. Peningkatan ini disebabkan karena adanya peningkatan transfer elektron antara permukaan elektroda GCE@NiFeOx dengan moekul dopamin dibandingkan dengan hanya menggunakan GCE. Kata-kata kunci: NiFeOx, dopamin, voltametri siklik, sensor elektrokimia. Abstract In this research, the fabrication and characterization of an electrochemical sensor electrode for the detection of dopamine, one of the biomarkers of Parkinson's disease, based on NiFeOx using the molten salt method, have been conducted. This research aims to investigate the effect of using KOH molten salt on the phase and morphology characterization, as well as the electrochemical sensor performance of NiFeOx. Cyclic voltammetry (CV) was performed to investigate electrochemical properties of the glassy carbon electrode (GCE) modified with NiFeOx (GCE@ NiFeOx) in detecting dopamine. CV measurement was carried out at a scan rate of 20-300 mV/s in a 1 mmol dopamine with 0.1 M PBS (Phosphate Buffered Saline) as a supporting electrolyte and potential range of -0.1 to 0.4 V vs Ag/AgCl. The results of CV analysis showed that the NiFeOx sample was sensitive to dopamine molecules, as indicated by an oxidation peak current of 12 µA. This enhancement was attributed to the increased electron transfer between the GCE@ NiFeOx electrode surface and dopamine molecules compared to using only GCE. Keywords: NiFeOx, dopamine, cyclic voltammetry, electrochemical sensor.
ANALISA AKURASI DATA CURAH HUJAN SATELITE TERHADAP DATA PENGUKURAN DI DAERAH TANGKAPANN AIR (DTA) WADUK SUTAMI Hermawan, Angga; Suharyanto
JURNAL REKAYASA Vol. 13 No. 1 (2023): Jurnal REKAYASA
Publisher : Fakultas Teknik Sipil dan Perencanaan. Universitas Bung Hatta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.37037/jrftsp.v13i1.139

Abstract

Waduk Sutami yang berada di dalam Wilayah Sungai Brantas merupakan waduk multiguna yang berfungsi sebagai penyedia air baku, irigasi, pengendali banjir , dan pembangkit listrik, kegiatan perikanan, serta pariwisata. Informasi data curah hujan sangat penting dalam analisis hidrologi sebagai dasar penentuan pola operasi , neraca air, hingga perhitungan laju sedimen. Data hujan yang runtut waktu pencatatannya dapat memberikan informasi tren atau kecenderungan dari sifat hujan namun pada kenyataannya untuk mendapatkan data pengamatan curah hujan yang representatif yaitu baik dalam hal kualitas maupun panjang data pengamatannya yang cukup sesuai dengan yang dipersyaratkan di beberapa lokasi sangatlah sulit dikarenakan ketiadaan stasiun hujan ataupun alat pengukur yang rusak. Oleh karena itu dengan memanfaatkan kemajuan teknologi perlu dilakukan analisa akurasi data curah hujan melalui satelit (GPM V6 dan TRMM 3B43 V7) sebagai alternatif penggunaan data curah hujan untuk mengisi kekurangan data pada lokasi tertentu. Hasil analisis kedua data hujan satelit (GPM V6 dan TRMM 3B43 V7) tersebut berdasarkan parameter Nash Sutcliffe Efficiency (NSE), Root Mean Square Errror (RMSE),Kesalahan Realtif (KR), Koefisien Korelasi (R) dapat digunakan sebagai alternatif data curah hujan, dengan data curah hujan satelit GPM V6 memiliki akurasi dan performa yang lebih baik.