IMPLEMENTATION OF LABORATORY MEASUREMENT OF AIRBORNE SOUND INSULATION BASED ON ISO AND ASTM STANDARDS IN NATIONAL STANDARDIZATION AGENCY OF INDONESIA (BSN) Bondan Dwisetyo; Maharani Ratna Palupi; Fajar Budi Utomo; Chery Chaen Putri; Dodi Rusjadi; Ninuk Ragil Prasasti; Denny Hermawanto
JURNAL STANDARDISASI Vol 23, No 1 (2021)
Publisher : Badan Standardisasi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31153/js.v23i1.861

Abstract

The implementation of laboratory measurement of airborne sound insulation based on ISO and ASTM standards was carried out at SNSU BSN. The aim of this work to realize the measurement of airborne sound insulation for several sample tests, where the procedure of the test is performed according to the updated standard ISO 10140 and ASTM E90. Besides, the single number rating also is determined based on ISO 717-1 and ASTM E413. This measurement has been conducted in the two reverberation rooms using pressure method consist of measuring the sound pressure level, measuring the reverberation time, obtaining the sound reduction index (R) or sound transmission loss (STL), and determination of a single-number ratings of the samples test. From the results, some parameter requirements such as the frequency range and the rounding procedure of R or STL influence the measurement result slightly. Subsequently, the significant difference is obtained for the determination of single number rating in the shifting procedure of the reference curve.
REALIZATION OF TOTAL HARMONIC DISTORTION MEASUREMENT OF ACOUSTIC SOURCE SIGNAL SYSTEM FOR FREQUENCY OF 125 HZ AND 1000 HZ Bondan Dwisetyo; Denny Hermawanto; Dodi Rusjadi; Chery Chaen Putri; Maharani Ratna Palupi; Fajar Budi Utomo
JURNAL STANDARDISASI Vol 21, No 3 (2019)
Publisher : Badan Standardisasi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31153/js.v21i3.794

Abstract

The measurement of total harmonic distortion (THD) of an acoustic source signal system has carried out in Laboratory Acoustics and Vibration, Sub-directorate of National Measurement Standards for Acoustics and Vibration - BSN. The aim of this research is, therefore, to measure and analize the THD values that produced by the system that consists of a signal generator, a power amplifier, and a passive loudspeaker with fundamental frequencies of 125 Hz and 1000 Hz. This measurement should be implemented because it has never been performed in this laboratory. Moreover, this system always be used for either calibration or measurement of acoustical instruments such as sound level meter and noise dosimeter. The method used to measure THD is a free field method using a full anechoic chamber with narrow band analysis. Measurand to determine THD is sound pressure level (SPL) with output of loudspeaker are 94 dB, 104 dB, and 114 dB. From result of measurement was found THD value of fundamental frequencies of 125 Hz and 1000 Hz. For the former frequency, the maximum THD was found at SPL of 94 dB where its value was 1,86 %. Meanwhile the later, the maximum value of THD was 1,94 % also at SPL 94 of dB. The results of this measurement can be used into uncertainty budget for either calibration or testing of acoustical instruments, and also support for validation of calibration of noise dosimeter based on percentage of noise exposure dose using acoustic comparison coupler that still under research and development in this year.