A STANDARDIZATION OF THE ELECTRICAL METROLOGY LABORATORY COMPETENCE FOR DC VOLTAGE UNIT Hadi Sardjono
JURNAL STANDARDISASI Vol 9, No 1 (2007): Vol. 9(1) 2007
Publisher : Badan Standardisasi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31153/js.v9i1.27

Abstract

Sebagai Laboratorium Metrologi Nasional, Puslit KIM-LIPI berkewajiban untuk memelihara salah satu besaran kelistrikan yaitu standar tegangan dc 10V. Proses pemeliharaan dilakukan berdasarkan ketertelusuran dan uji banding antar laboratorium metrologi nasional negara lain. Pada proses ketertelusuran dipenuhi dengan mengkalibrasi sel standar 10V ke laboratorium Nasional Australia (NMIA). Sedangkan proses uji banding dilakukan bekerjasama dengan laboratorium nasional Singapura (SPRING). Dari hasil uji banding diperoleh nilai validasi kompetensi berdasarkan nilai En yaitu sebesar –0.25.
PENETAPAN NILAI KETIDAKPASTIAN BAKU SISTEM PENGUKURAN METODE TIDAK LANGSUNG SATUAN KELISTRIKAN DAYA SATU FASA PADA SKALA LABORATORIUM Hadi Sardjono
JURNAL STANDARDISASI Vol 8, No 3 (2006): Vol. 8(3) 2006
Publisher : Badan Standardisasi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31153/js.v8i3.668

Abstract

As a national laboratory, Puslit KIM-LIPI has been realised it measurement capability for ac power in form of Power Source System which is performed in combination of an ac voltage source, an ac current source and a pahse shifter from 00 up to 3600. Concerning to the accuracy maintenance, it was observed by using an indirect measurement method. This measurement system was involved a several equipment standards such as a DMM (Digital Multimeter) and a wattmeter as the load and the voltage and the current value supply by the power source were measured with it accuracy limmitation up to 0.8%.
PERANCANGAN CHAMBER DENGAN SUHU TERKONDISI UNTUK FREKUENSI STANDAR PADA KESTABILAN MENCAPAI 4,6x10-15 Hadi sardjono; Boynawan .; Ratnaningsih .; lukluk .
JURNAL STANDARDISASI Vol 13, No 1 (2011): Vol. 13(1) 2011
Publisher : Badan Standardisasi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31153/js.v13i1.32

Abstract

Cesium beam dan Hydrogen Maser adalah dua tipe pembangkit frekuensi yang ditetapkan sebagai standar nasional oleh laboratorium metrologi Kelistrikan Puslit KIM–LIPI. Ketelitian besaran frekuensi ini terjaga oleh proses pembandingan UTC–UTC (KIM) dibawah koordinasi sebuah lembaga metrologi Internasional BIPM (Bureau International das Poids at Measures). Berdasarkan proses pembandingan selama 9 bulan telah terbentuk sebuah karakteristik kestabilan frekuensi melalui sebuah grafik suhu ruang versus kesalahan frekuensi relatif, sehingga diperoleh rentang suhu ruang optimum pada kesalahan relatif minimal mencapai 4,6x10-15