IMPLEMENTASI SOLAR TRACKER PADA PLTS OFF GRID UNTUK SISTEM PENDETEKSI BANJIR Faturrachman, Luthfi; Rozak, Ojak Abdul; Multi, Abdul; Samiaji, Ghani
Electro Luceat Vol 10 No 2 (2024): Elektro Luceat- November 2024
Publisher : LPPM Poltek ST Paul

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32531/jelekn.v10i2.822

Abstract

Solar energy is an inexhaustible renewable energy resource. This can also be used as energy that can be converted into electricity. Due to the importance of using electrical energy, electricity network management companies in Indonesia continue to experience price per kwh increases in proportion to the increasing amount of electrical energy consumption. Therefore, alternative energy is needed which functions as an energy generator. On this basis, the author tries to design a power plant using solar power. This test uses two methods, before using the solar tracker and after using the solar tracker. The results of calculating the average power value for ten days of testing before using the solar tracker were 44.3 watts, and the results of calculating the average power value for ten days of testing after using the solar tracker were 53.1 watts. The results of comparing the average power value before and after the implementation of the solar tracker showed an increase in power value of 8.8 watts. The off-grid solar system is able to meet the needs of the system load. The implementation of the use of solar trackers on solar panels is able to increase the value of the generated power.
ANALISIS PERBANDINGAN KUALITAS DAYA LISTRIK BERDASARKAN HARMONISA PADA MOTOR LISTRIK DENGAN SUPLAI TENAGA SURYA DAN PLN Samiaji, Ghani; Multi, Abdul; Rozak, Ojak Abdul; Faturrachman, Luthfi
Jurnal Informatika dan Teknik Elektro Terapan Vol 12, No 3 (2024)
Publisher : Universitas Lampung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.23960/jitet.v12i3.4876

Abstract

PLTS off-grid adalah pembangkit listrik yang tidak terhubung ke jaringan dan menggunakan media penyimpanan seperti baterai untuk menyimpan daya pada malam hari atau pada saat intensitas matahari berkurang serta pada saat listrik padam dari PLN.  Penelitian ini membahas tentang THD pada beban motor listrik dengan sumber yang digunakan untuk melakukan pengukuran serta analisis plts off-grid dan sumber pln, setelah itu, dilakukan perbandingan pada harmonisa arus dan tegangan, lalu kemudian disimulasikan menggunakan software ETAP 12.6. Hasil penelitian dan analisis nilai harmonisa dengan mengambil nilai rata-rata THDv dan THDi pada motor listrik 1 fasa, lalu dilakukan perbandingan dengan standard yang berlaku yaitu Standard Institute of Electrical and Electronic Engineers (IEEE) 519: 2014). Kemudian dihitung menggunakan persamaan. Hasil analisis menunjukkan nilai THDv pada motor listrik yang bersumber dari PLN dan PLTS sebesar 2,3 % yang berarti masih dalam batas standar dan hasil deviasi sebesar 0%. Sedangkan nilai THDi pada motor listrik yang bersumber dari PLN sebesar 7,7 % serta sumber dari PLTS sebesar 7,2 % yang berarti dari kedua pengukuran masih dalam batas standar IEEE dan terjadi perbandingan pengukuran THDi tersebut dengan nilai sebesar 6,4 %. Nilai perbandingan tersebut dapat mempengaruhi kualitas daya listrik
IMPLEMENTASI SOLAR TRACKER PADA PLTS OFF GRID UNTUK SISTEM PENDETEKSI BANJIR Faturrachman, Luthfi; Rozak, Ojak Abdul; Multi, Abdul; Samiaji, Ghani
Electro Luceat Vol 10 No 2 (2024): Elektro Luceat- November 2024
Publisher : LPPM Poltek ST Paul

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32531/jelekn.v10i2.822

Abstract

Solar energy is an inexhaustible renewable energy resource. This can also be used as energy that can be converted into electricity. Due to the importance of using electrical energy, electricity network management companies in Indonesia continue to experience price per kwh increases in proportion to the increasing amount of electrical energy consumption. Therefore, alternative energy is needed which functions as an energy generator. On this basis, the author tries to design a power plant using solar power. This test uses two methods, before using the solar tracker and after using the solar tracker. The results of calculating the average power value for ten days of testing before using the solar tracker were 44.3 watts, and the results of calculating the average power value for ten days of testing after using the solar tracker were 53.1 watts. The results of comparing the average power value before and after the implementation of the solar tracker showed an increase in power value of 8.8 watts. The off-grid solar system is able to meet the needs of the system load. The implementation of the use of solar trackers on solar panels is able to increase the value of the generated power.
ANALISIS PERBANDINGAN KUALITAS DAYA LISTRIK BERDASARKAN HARMONISA PADA MOTOR LISTRIK DENGAN SUPLAI TENAGA SURYA DAN PLN Samiaji, Ghani; Multi, Abdul; Rozak, Ojak Abdul; Faturrachman, Luthfi
Jurnal Informatika dan Teknik Elektro Terapan Vol. 12 No. 3 (2024)
Publisher : Universitas Lampung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.23960/jitet.v12i3.4876

Abstract

PLTS off-grid adalah pembangkit listrik yang tidak terhubung ke jaringan dan menggunakan media penyimpanan seperti baterai untuk menyimpan daya pada malam hari atau pada saat intensitas matahari berkurang serta pada saat listrik padam dari PLN.  Penelitian ini membahas tentang THD pada beban motor listrik dengan sumber yang digunakan untuk melakukan pengukuran serta analisis plts off-grid dan sumber pln, setelah itu, dilakukan perbandingan pada harmonisa arus dan tegangan, lalu kemudian disimulasikan menggunakan software ETAP 12.6. Hasil penelitian dan analisis nilai harmonisa dengan mengambil nilai rata-rata THDv dan THDi pada motor listrik 1 fasa, lalu dilakukan perbandingan dengan standard yang berlaku yaitu Standard Institute of Electrical and Electronic Engineers (IEEE) 519: 2014). Kemudian dihitung menggunakan persamaan. Hasil analisis menunjukkan nilai THDv pada motor listrik yang bersumber dari PLN dan PLTS sebesar 2,3 % yang berarti masih dalam batas standar dan hasil deviasi sebesar 0%. Sedangkan nilai THDi pada motor listrik yang bersumber dari PLN sebesar 7,7 % serta sumber dari PLTS sebesar 7,2 % yang berarti dari kedua pengukuran masih dalam batas standar IEEE dan terjadi perbandingan pengukuran THDi tersebut dengan nilai sebesar 6,4 %. Nilai perbandingan tersebut dapat mempengaruhi kualitas daya listrik