p-Index From 2020 - 2025
0.408
P-Index
This Author published in this journals
All Journal Rekayasa Mesin
Danang, Setio Wardana
Unknown Affiliation

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

ANALISIS KUALITAS GAS BUANG PADA STEAM BOILER BERBAHAN BAKAR BIO-SOLAR DAN BATU BARA Ar Rasyid, Moh. Rizal; Anis, Samsudin; Susanto, Susanto; Danang, Setio Wardana
Jurnal Rekayasa Mesin Vol. 15 No. 3 (2024)
Publisher : Jurusan Teknik Mesin, Fakultas Teknik, Universitas Brawijaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21776/jrm.v15i3.1783

Abstract

Steam boilers fueled by biodiesel and coal are one of the industrial activities that still produce exhaust emissions such as Total Particulate (PM), Sulfur Dioxide (SO2), Opacity, Nitrogen Oxide (NOx), and Carbon Monoxide (CO) which is very dangerous for public health and the environment. Therefore, analysis of flue gas emissions in steam boiler installations equipped with filtration devices (cyclones, water scrubbers, and electrostatic precipitators) before being discharged into the environment is of important. Exhaust gas emission was measured by using a gas analyzer, smoke tester, and portable quality air monitor. The results of exhaust gas emission analysis showed that the average concentration of PM, SO2, and CO did not meet the specified emission quality standard thresholds, exempted for opacity concentration for both steam boilers fueled with biodiesel and coal. It is suspected that this is caused by the sub optimal performance of the filtration equipment used in this system. Therefore, regular maintenance is required, and if necessary, a redesign of the entire system can be carried out.
ANALISIS KUALITAS GAS BUANG PADA STEAM BOILER BERBAHAN BAKAR BIO-SOLAR DAN BATU BARA Ar Rasyid, Moh. Rizal; Anis, Samsudin; Susanto, Susanto; Danang, Setio Wardana
Jurnal Rekayasa Mesin Vol. 15 No. 3 (2024)
Publisher : Jurusan Teknik Mesin, Fakultas Teknik, Universitas Brawijaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21776/jrm.v15i3.1783

Abstract

Steam boilers fueled by biodiesel and coal are one of the industrial activities that still produce exhaust emissions such as Total Particulate (PM), Sulfur Dioxide (SO2), Opacity, Nitrogen Oxide (NOx), and Carbon Monoxide (CO) which is very dangerous for public health and the environment. Therefore, analysis of flue gas emissions in steam boiler installations equipped with filtration devices (cyclones, water scrubbers, and electrostatic precipitators) before being discharged into the environment is of important. Exhaust gas emission was measured by using a gas analyzer, smoke tester, and portable quality air monitor. The results of exhaust gas emission analysis showed that the average concentration of PM, SO2, and CO did not meet the specified emission quality standard thresholds, exempted for opacity concentration for both steam boilers fueled with biodiesel and coal. It is suspected that this is caused by the sub optimal performance of the filtration equipment used in this system. Therefore, regular maintenance is required, and if necessary, a redesign of the entire system can be carried out.