Rancang Bangun Infusion Pump Dengan Pemantauan Riwayat Pemberian Cairan Infus Pada Pasien Dilengkapi Website Pratama, I Gusti Agung Ngurah Devasya Putra; Suhartono, Suhartono; Sutrisnawati, Ni Nyoman Dwi; Mahardiananta, I Made Agus
TELKA - Telekomunikasi Elektronika Komputasi dan Kontrol Vol 11, No 1 (2025): TELKA
Publisher : Jurusan Teknik Elektro UIN Sunan Gunung Djati Bandung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.15575/telka.v11n1.52-63

Abstract

Infusion pump merupakan peralatan medis yang digunakan untuk memantau proses pemberian cairan ke dalam tubuh melalui intravena. Infusion pump mengatur cairan yang keluar dan memberikan indikator alarm ketika terjadi permasalahan pada proses terapi infus. Permasalahan yang sering terjadi adalah pemantauan infusion pump yang tidak dapat dilakukan secara jarak jauh sehingga perawat memiliki mobilitas yang tinggi untuk infusion pump. Pada penelitian ini dihasilkan rancang bangun alat nfusion pump yang dapat memantau kondisi terapi infus secara nirkabel. Menggunakan Optocoupler XD-51 sebagai sensor tetesan dan sensor gelembung udara, Photodioda FC-51 sebagai sensor darah naik pada selang, motor peristaltik sebagai pengatur flow rate, Node MCU ESP32 sebagai mikrokontroler, Firebase sebagai database pasien, website sebagai sistem wireless monitoring kondisi terapi infus. Back end website monitoring rancang bangun alat menggunakan Firebase Realtime dan front end website menggunakan Visual Studio Code. Dari hasil penelitian diperoleh persentase nilai rata-rata pengujian keakurasian flow rate 500 mL / 6 jam sebesar 97.6%, flow rate 500 mL / 8 jam sebesar 97.5%, dan waktu respon sistem alarm darah naik sebesar 5 detik, sistem alarm gelembung udara sebesar 5.2 detik, sistem alarm infus macet sebesar 7.3 detik serta pengujian terhadap sistem penyimpanan riwayat data dengan tinggat keakurasian sebesar 100%. Berdasarkan acuan nilai tolerasi error yang diijinkan pada infusion pump adalah sebesar 5% dengan waktu respon alarm sebesar 10 detik, maka dapat disimpulkan bahwa alat rancang bangun dapat bekerja sebagaimana mestinya dengan nilai persentase error yang masih dalam batas toleransi yang diperboleh sesuai dengan alat acuan. The infusion pump is a critical medical device for the controlled delivery of fluids through intravenous routes. It ensures precise regulation of fluid administration and includes an alarm system to signal issues during the infusion therapy process. However, the limitation lies in the inability to remotely monitor these pumps, leading to mobility challenges for nurses. To address this, a remote monitoring infusion pump was developed. It incorporates various components such as the Optocoupler XD-51 for detecting droplets and air bubbles, the FC-51 Photodioda to sense blood rising within the hose, a peristaltic motor for flow rate control, an ESP32 MCU Node as the central controller, Firebase for patient data storage, and a dedicated website for wireless monitoring. The backend of the website utilizes Firebase Realtime, while the frontend is developed using Visual Studio Code. Research findings indicate high accuracy in flow rate measurements, with 97.6% accuracy for 500 mL over 6 hours and 97.5% accuracy for 500 mL over 8 hours. Alarm response times, though slightly delayed, are within acceptable limits: the blood alarm system responds in 5 seconds, the air bubble alarm system in 5.2 seconds, and the infusion alarm system in 7.3 seconds. Furthermore, the data history storage system demonstrated 100% accuracy. Given that the reference values allow for a 5% error tolerance and require a 10-second alarm response time, it can be concluded that this designed tool effectively meets the necessary standards and functions within the allowable tolerance limits.
Rancang Bangun Blood Roller Mixer Digital dengan Penambahan Mode Kecepatan dan Waktu Mahardiananta, I Made Agus; Dharmayanti, Cokorda Istri; Pratama, I Gusti Agung Ngurah Devasya Putra
TELKA - Telekomunikasi Elektronika Komputasi dan Kontrol Vol 10, No 3 (2024): TELKA
Publisher : Jurusan Teknik Elektro UIN Sunan Gunung Djati Bandung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.15575/telka.v10n3.193-203

Abstract

Pemeriksaan hematologi adalah pemeriksaan cairan darah yang berhubungan dengan sel darah dan biokimia yang berhubungan dengan sel darah. Selama pemeriksaan, sering dijumpai gumpalan darah karena darah mengandung koagulan. Untuk menghindari hal tersebut, darah harus dicampur dengan antikoagulan (antikoagulan) dan proses pencampurannya dibantu dengan alat laboratorium yaitu blood roller mixer. Blood roller mixer adalah alat yang digunakan untuk mengocok sampel darah yang berada di dalam venoject yang telah diberi anti koagulan sebagai zat yang dapat mencegah penggumpalan darah, agar mendapatkan darah dalam keadaan homogen. Alat ini dirancang dengan pengaturan kecepatan dan waktu digital, diharapkan kesalahan pembacaan kecepatan dan waktu dapat diminimalkan dan lebih mudah digunakan. Metode yang digunakan dalam penelitian ini adalah deskriptif eksploratif, pengolahan data kecepatan dan waktu menggunakan SPSS dengan uji Wilcoxon. Berdasarkan hasil analisis yang telah dilakukan dengan mem-bandingkan kecepatan dengan tachometer dan waktu dengan stopwatch, hasil dari kedua parameter tersebut tidak berbeda signifikan dengan nilai uji perbandingan pada masing-masing setting yang tidak melebihi nilai 0,05. A hematological test examines blood fluids and biochemistry associated with blood cells. Blood clots are frequently seen during examinations with blood cells. To avoid this, blood must be combined with an anticoagulant and assisted in the mixing process by laboratory equipment, namely a blood roller mixer. A blood roller mixer is an equipment used to shake blood samples in a venoject that has been treated with an anti-coagulant to avoid blood clots, in order to get homogeneous blood. This tool is created with digital speed and time options, with the goal of reducing mistakes and it easier to use. This study employed a descriptive exploratory strategy with, SPSS and the Wilcoxon test to process data in terms of speed and time. According to the findings of the analysis, wichh involved comparing speed with a tachometer and time with a stop-watch, the results of the two parameters are not significantly different from the comparison test values in each setting which do not exceed the value of 0.05.