Claim Missing Document
Check
Articles

Found 2 Documents
Search

Analysis of Corrosion Rate of Carbon Steel Galvanized by Weight Loss Method to Thickness and Micro Structure of Steel Mohamad Agus Fhaizal
VANOS Journal of Mechanical Engineering Education Vol 6, No 1 (2021)
Publisher : Universitas Sultan Ageng Tirtayasa

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30870/vanos.v6i1.10913

Abstract

This study aims to determine the effect of hot dip galvanizing on steel with different carbon content on mechanical properties of steel. The research method used in this research is an experimental method,The method used was that the metal was coated with hot dip galvanizing media using zinc. From the hardness test results, SAE 1085 produced the highest average of hardness 95.1 HRB. The results of the thickness test showed that the highest AISI 1020 was 131.8 μm. The results of the corrosion rate test showed that the highest corrosion rate is AISI 1020 was 0.36385 mmpy. The microstructure test results showed SAE 1085 has a smaller grain size. Zn layer which is not too thick due to lack of diffusion and movement of Zn atoms due to high carbon content which has a close layer distance and small grains. So that the corrosion rate that occurs is lower than steel which has a low carbon content.
ANALISIS PERAWATAN MESIN DRINKING WATER DENGAN METODE RELIABILITY CENTERED MAINTENANCE (RCM) Fadhal; Solehudin, Agus; Mulyadi, Cecep Deni; Fhaizal, Mohamad Agus
TECHNO-SOCIO EKONOMIKA Vol 17 No 2 (2024): Jurnal Techno-Socio Ekonomika - Oktober
Publisher : LPPM Universitas Sangga Buana

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32897/techno.2024.17.2.3746

Abstract

The company where author currently work is at PT Angkasa Pura Solusi a subsidiary of PT Angkasa Pura II (Persero) Soekarno-Hatta International Airport, the author in Water Treatment unit as a senior technician. This unit is responsible for operating, maintaining, and repairing clean water distribution equipment to terminals and buildings at Soekarno-Hatta Airport as well as overcoming disturbances, repairing, replacing, and maintain the equipment at Soekarno-Hatta International Airport in accordance with applicable regulations. One of the responsibilities is the maintenance of Drinking Water Machine equipment, for current conditions maintenance of Drinking Water Machine equipment is only carried out if there are complaints of problems by telephone. For scheduled or planned maintenance has been carried out but is still not effective. The result is that the tool experiences a short lifetime on the supporting components of the Drinking Water Machine tool which makes the tool unable to operate properly and leads to budget overruns because they have to continue to replace damaged spare parts components so that the tool can operate optimally at performance figures above 90%, in addition to the impact caused by equipment operational downtime due to lack of preparation when the Drinking Water Machine tool must be repaired. For this reason, the author makes a maintenance analysis of the Drinking Water Machine with the Reliability Centered Maintenance (RCM) method, from this method it will be known what components of the Drinking Water Machine are often damaged or malfunctioned.