PENEGAKAN DIAGNOSTIK YANG OPTIMAL PADA KLINIS HERNIA NUKLEUS PULPOSUS DENGAN PEMERIKSAAN LUMBOSACRA DI INSTALASI RADIOLOGI RUMAH SAKIT UMUM DAERAH PANTURA M.A SENTOT PATROL INDRAMAYU 2019 MUHAMMAD RAIZA RAFINDI; TRI SUWARTINI; YUKI MULYANI
Jurnal Kesehatan Pertiwi Vol 4 No 2 (2022): Jurnal Kesehatan Pertiwi (Vol. 4 No. 2 - Desember 2022)
Publisher : Poltekes Bhakti Pertiwi Husada

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Tujuan : Untuk memperoleh informasi diagnostik yang optimal pada Pemeriksaan Lumbosacral pada klinisHernia Nukleus Pulposus di Instalasi Radiologi Rumah Sakit Umum Daerah Pantura M.A Sentot Patrol Indramayu. Metodologi penelitian : Metodologi penelitian yang digunakan adalah kualitatif dengan metode deskriptif analitik intrumen yang digunakan observasi lapangan dan pengisian kuisioner oleh radiiografer RSUD Pantura M.A Sentot Patrol Indramayu mengenai penegakan diagnostik yang optimal pada pemerikaaan lumbosacral.Hasil :Penatalaksanaan pemeriksaan lumbosacral pada klinisHernia Nukleus Pulposus di Instalasi Radiologi RSUD Pantura M.A Sentot Patrol Indramayu menggunakan dua proyeksi yaitu AP dan Lateral dengan FFD 100cm .
PERBANDINGAN SEQUENCE T1 WEIGHTED IMAGE SPIN ECHO DENGAN T1 FLUID ATTENUATED INVERSION RECOVERY (FLAIR) TERHADAP KUALITAS GAMBAR MRI BRAIN POTONGAN AXIAL DI RS DUSTIRA CIMAH YUKI MULYANI; RORY AGUSTRIA
Jurnal Kesehatan Pertiwi Vol 5 No 2 (2023): Jurnal Kesehatan Pertiwi (Vol. 5 No.2 - Desember 2023)
Publisher : Poltekes Bhakti Pertiwi Husada

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Penelitian ini bertujuan untuk mendapatkan kualitas gambar yang lebih baik antara sequence T1 weighted image Spin Echo (SE) dengan T1 Fluid Attenuated Inversion Recovery (FLAIR) pada pemeriksaan MRI brain potongan axial di RS Dustira Cimahi. Penelitian dilakukan dengan metode observasi pendekatan deskriptif analitik. Sampel diambil dari sebagian populasi pemeriksaan MRI brain yaitu pasien yang pada potongan axial pembobotan T1 menggunakan sequence Spin Echo dan FLAIR. Hasil penelitian dari perbandingan kedua sequence tersebut adalah nilai SNR lebih baik pada sequence T1 SE dan nilai CNR lebih baik pada sequence T1 FLAIR
PERHITUNGAN NILAI NOISE APLIKASI SOFTWARE IMAGEJ DENGAN VARIASI PIXEL SIZE MENGGUNAKAN FOV 375, FOV 395, FOV 415 DENGAN MATRIX SIZE SAMA PADA PEMERIKSAAN CT SCAN ABDOMEN MUHAMMAD RAIZA RAFINDI; YUKI MULYANI
Jurnal Kesehatan Pertiwi Vol 5 No 1 (2023): Jurnal Kesehatan Pertiwi (Vol. 5 No.1 - Juli 2023)
Publisher : Poltekes Bhakti Pertiwi Husada

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

FOV( Field of View ) is the diameter of the maximum and the picture which will be reconstructed. Has been conducted research program application the use of field of fiew for reckoning the pixels size against noise on CT scans the abdomen is. The aim of this research is to find out the influence of the variation of pixels size by using FOV 373, 395, and 415 with the same matrix size against noise on CT scans the abdomen is. A kind of this research deskriftif with the approach of quantitative. The study is done in the department of radiologist RSUD Indramayu. To obtain data in this research, the use writers a method of collecting data by means of observations directly with comparing workup CT scans the abdomen with 3 times comparing variation FOV. After that, the result is taken from a snippet axial the same against samples. Several pictures be judged by imageJ and counted the use of tabulating with the formula noise, and the result analysis meggunakan the result of calculating standard deviations from noise on 3 variation FOV used in descriftive. The results showed an increase in the value of the results of the use of noise variation pixel size by using the FOV 375, 395, and 495 with matrix of the same size of the noise on a CT Scan of the abdomen that is for FOV 375 with an average of 8.98 and std. deviation of 0.89, FOV 395 with an average of 9.84 and std. deviation 1.63, and to the FOV 415 with an average 10.86 and std. deviation of 2.31.
PERBANDINGAN TEKNIK GRADIENT ECHO DENGAN TEKNIK FAST SPIN ECHO DALAM MEMPERLIHATKAN CARTILAGO ARTICULATIO GENU PADA PEMERIKSAAN MRI GENU POTONGAN SAGITAL DI RUMAH SAKIT TK.II 03.05.01 DUSTIRA ZIKO PRATAMA; YUKI MULYANI
Jurnal Kesehatan Pertiwi Vol 6 No 1 (2024): Jurnal Kesehatan Pertiwi (Vol. 6 No.1 - Juni 2024)
Publisher : Poltekes Bhakti Pertiwi Husada

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Telah dilakukan penelitian tentang penggunaan teknik Gradient Echo dan Fast Spin Echo pada cartilage articulatio di Rumah Sakit Satya Negara pada bulan Agustus-Oktober tahun 2012. Penelitian ini bertujuan untuk mengetahui perbedaan gradient echo dan fast spin echo dalam memperlihatkan cartilage pada articulatio genu dan untuk mengetahui sekuen mana yang lebih bagus memperlihatkan cartilage. Penelitian dilakukan dengan metode observasi pendekatan analitik kuantitatif. Data diambil dengan membuat gambaran MRI teknik gradient echo dan fast spin echo pada potongan sagital. Penilaian hasil gambaran dilakukan oleh 10 orang responden yang berprofesi sebagai dokter radiolog dan radiografer dengan metode kuisioner untuk mendapatkan hasil gambaran yang lebih baik dalam memperlihatkan cartilago articulatio genu. Data yang diperoleh dilakukan uji statistik dengan uji T Test untuk menentukan perbedaan nilai diantara kedua gambar tersebut. Hasil penelitian menunjukkan bahwa ada perbedaan informasi yang signifikan antara Gradient Echo dan Fast Spin Echo pada cartilage articulatio genu potongan sagital (p value = 0,00 < 0,05) yang berarti ada perbedaan hasil gambaran yang signifikan antara gradient echo dan fast spin echo pada daerah cartilage. Dari penelitian tersebut dapat disimpulkan bahwa teknik gradient echo lebih baik dalam memperlihatkan cartilago dibandingkan dengan teknik fast spin echo.