Claim Missing Document
Check
Articles

Found 2 Documents
Search

Flux Analysis with the Application of Darcy’s Law Based on Borehole Data for Sustainable Groundwater Exploitation Fadhli, Zul; Khirnica, Khaira; Syukri, Muhammad; Miska, Layna; Marvita, Yurda; Marwan, Marwan; Dharma, Dian Budi
Jurnal Ilmu Lingkungan Vol 23, No 2 (2025): March 2025
Publisher : School of Postgraduate Studies, Diponegoro Univer

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14710/jil.23.2.410-417

Abstract

The potential for groundwater is very large and widely distributed in Aceh Besar District as indicated by the Groundwater Basin map. This potential is supported by the presence of sedimentary deposits consisting of materials such as gravel, sand and clay. This research was conducted to identify the type of aquifer and calculate the amount of groundwater discharge in the district of Aceh Besar. The discharge calculation is carried out using Darcy's Law where this equation can be used to describe the ability of the aquifer to flow through the rock. This study also compares the results of calculating the water discharge using Darcy's Law with the real Pumping Test data. The results showed that the coastal area of Aceh Besar was dominated by confined aquifers with average depth of 40-120 m and thickness of 3-30 m. The results of calculating the water discharge (flux) in the study area were obtained around 3414.61 m/day or equivalent to 39.51 liters/second. The results of comparison with the real Pumping Tes data in segment 2 found that the results of calculating discharge using Darcy's Law were 23.93 liters/second while the results of real Pumping Test were 25.5 liters/second so that the error value found is 6.1%, and in segment 3 the results of calculating discharge using Darcy's Law is 21.88 liters/second while the results of the real Pumping Test are 21 liters/second so that an error value of 4.2%.. From the results of these two comparisons, it can be seen that the calculation of water discharge using Darcy's Law is comparable and has significant results with the results obtained from the real Pumping Test, so that the calculation of water discharge using Darcy's Law can be used for a reference in the groundwater exploitation.
Identifikasi karakteristik akuifer di kawasan perumahan PT. PIM (Pupuk Iskandar Muda) Aceh Utara menggunakan metode geolistrik resistivitas 1-D Miska*, Layna; Fadhli, Zul; Zya, Putroe Salsabilla; Marvita, Yurda; Khirnica, Khaira; Tarmizi, Tarmizi; Hasanah, Uswatun
Acta Geoscience, Energy, and Mining Vol 3, No 2 (2024): June 2024
Publisher : Departemen Teknik Kebumian Universitas Syiah Kuala

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24815/actaGEM.v3i2.38841

Abstract

Telah dilakukan kajian struktur bawah permukaan untuk mengindentifikasi karakter akuifer di kawasan perumahan PT. Pupuk Iskandar Muda Aceh Utara. Penelitian ini dilakukan menggunakan metode geolistrik Resistivitas 1D dengan konfigurasi Wenner. Pengukuran dilakukan pada 4 titik berdekatan dengan menginjeksikan arus listrik ke bawah permukaan sehingga diperoleh nilai resistivitas setiap lapisan bawah permukaan. Lintasan titik 1 (T1) dan titik 2 (T2) berada di koordinat yang berdekatan dan merupakan zona konservasi sedangkan lintasan titik 3 (T3) dan titik 4 (T4) berada di lapangan, dengan panjang masing-masing lintasan adalah 300 m. Pengolahan data untuk menghasilkan nilai inversi menggunakan perangkat lunak EarthImager 1D. Hasil penelitian menunjukkan adanya Formasi Idi dengan susunan batuan yang terdiri dari kerikil pasir, lempung, dan batu gamping, serta satuan batuan aluvium muda. Pada lokasi penelitian, lapisan pasir (13,8m 23,0m) diinterpretasikan sebagai lapisan akuifer dikarenakan pasir memiliki nilai porositas dan permeabilitas yang sesuai sebagai lapisan penyimpan air tanah. Berdasarkan karakteristik lapisan akuifer, diketahui bahwa jenis akuifer pada wilayah penelitian adalah akuifer tertekan dengan lapisan penutup berupa akuiklud/akuitard.