Sukati Saidin
Puslitbang Gizi dan Makanan, Badan Litbangkes Depkes RI

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

PROFIL BIOKIMIA DARAH PEKERJA LAKI-LAKI DENGAN KATEGORI RINGAN DAN BERAT Yuniar Rosmalina; Fitrah Ernawati; Sukati Saidin
Penelitian Gizi dan Makanan (The Journal of Nutrition and Food Research) Vol. 32 No. 1 (2009)
Publisher : Persagi

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22435/pgm.v32i1.1472.

Abstract

Biochemical Profile of Male Workers According To Hard or Light Works.Background: Various occupations could be categorized as light, moderate and heavy activities as well. Heavy workers by mean those who mainly work based on muscle strength usually received low salary, therefore they have low purchasing power for providing better nutrition, including for adequate energy intake. In contrary for those who work mainly using brain capacity rather than muscle strength usually received higher salary and consumed food with high content of fat. The difference of income could result difference of nutrition intake, even different impact to health/nutrition status and sensitivity to certain diseases as well. The profile of nutritional biochemistry could indicate the health status of people.Objectives: To study the relationship between biochemical profile of worker and different type of work.Methods: The subjects were 43 worker of sandal handicraft considered as light level workers and 44 workers of sand and stone as heavy workers whose met criteria 30-55 years old, physically healthy and agreed to involve in this study. Body composition was measured using anthropometry and blood analysis. Anthropometric measurement was applied including body weight, height, MUAC and skin fold thickness. Blood analysis was hemoglobin, albumin, protein and triglyceride. Nutrient intake was collected by combination weighing and 24 hours recall method for 3 consecutive days. Other data collection includes physical examination by a medical doctor and interview was done to identify their characteristic and socio demografi.Results: The proportion of workers who had serum albumin below normal was higher in heavy worker compared to light worker (56.8% vs. 23.3%). This finding indicated that more than half of hard workers had protein depletion as result of break down protein stores in thebody. The average of serum albumin of light workers was significantly higher compared to heavy workers. No significantly different based on the hemoglobin, protein and triglyceride concentration between the heavy and the light workers. The average energy and protein intake shows the heavy worker had higher intake on both nutrients compared to the lightworkers. The average energy intake of light worker was 1923 ± 295 Kcal and protein 41.6 ± 8.99 g, while the energy intake of heavy worker was 2232 ± 500 Kcal and protein 46.7 ± 14.7g.Conclusions: There was no significantly different found regarding biochemical profile oftwo workers, except serum albumin concentration. The lower profile of serum albumin concentration indicated that the heavy workers sacrificed of prolonged protein depletion of the body.Keywords: hemoglobin, protein, albumin, triglyceride, male worker.
CARA DETEKSI YODIUM SEMI-KUANTITATIF SEDERHANA PADA GARAM RUMAH TANGGA: UJI KELAYAKAN DI LAPANGAN Suryana Purawisastra; Sukati Saidin; Djoko Kartono; Dhuto Widagdo
Penelitian Gizi dan Makanan (The Journal of Nutrition and Food Research) Vol. 32 No. 1 (2009)
Publisher : Persagi

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22435/pgm.v32i1.1473.

Abstract

A Simple Field Kit-Test For Semi-Quantitative Iodine Content In The Iodated Salt of Households: An Appropriate-Test In The Field.Background: A programme of iodized salt for human consumption has been in operation in Indonesia for over 3 decades. Effectiveness of the programmed is to control and regular monitoring of edible salt for iodine. Therefore, it is required a simple field kit for semi quantitative estimation of iodine content in the iodated salt in the households.Methods: Thetest was performed by forty-five of house wives and forty-five of "kader". The samples of salt respectively were provided from their houses. The test was carried out by dropping of 2-3 drops of test-kit solution to surface of the salt. Observe the color appears on the surface of salt, and then compare to the color of photo of standard. The yellow color (code 1) was equalto 0 part per million of iodine (0 ppm), the color of yellow greenish (code 2) was equal to the iodine content of upper zero up to 15 ppm (>0 ppm - <15 ppm), the color of green yellowish (code 3) was equal to the iodine content between upper 15 to the below of 30 ppm (>15 ppm- < 30 ppm), and the color of green bluish (code 4) was equal to 30 ppm and above (> 30ppm). As comparison, the samples of salt were also analyzed quantitatively for the iodine content in laboratory using the standard method.Results: The result of iodine analysis in sample of salt done by using the standard method in the laboratory showed that the iodine content was varied. The estimate precision of iodine content in the salt by the house wives were 63,6% for the iodine content > 0 ppm-< 15 ppm; 87.5% for the iodine content > 15 ppm- < 30 ppm; 61.1% for the iodine content >30 ppm. While"kader" were 37,5% for the iodine content > 0 ppm - <15 ppm; 86.7% for the iodine content > 15 ppm - < 30 ppm; 72.7% for the iodine content > 30 ppm. Its Predictive Positive Value (PPV) in the iodine content 15 ppm > -< 30 ppm was 88% for the house wives and 87% for "kader". Its sensitivity was above 45% and its true prevalence (Se + Sp) was above 100% for all iodine concentration, except for zero ppm.Conclusions: The highest precisian of the simple field kit in estimation of iodine content in the salt was in the content > 15 ppm -< 30 ppm, that were 87.5% for house wives and 86.7% for "kader". It's Predictive Positive Value (PPV) in that iodine concentration was 88% for the house wives and 87% for the caders. Its sensitivity was above 45% and its true prevalence (Se + Sp) was above 100% for all iodine concentration.Recomendatlons: Further test for this field kit was suggested to be performed particularly its stability during storage.Keyswords: Iodated salt, a simple field kit, semi-quantities.