Claim Missing Document
Check
Articles

Found 2 Documents
Search

Characterization and mechanical properties of biocomposite of cantula fiber reinforced nano-ha/magnesium/shellac for bone screw material Triyono, Joko; Utami, Dea Pawestry; Rahardjo, Wijang Wisnu; Nugroho, Fransiskus Bima Widi
Jurnal Teknosains Vol 14, No 2 (2025): June
Publisher : Universitas Gadjah Mada

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22146/teknosains.106420

Abstract

Accidents are a major cause of fractures in Indonesia. One of treatments for fractures is bone screws with support plates that are placed on broken bone. Currently, many biomaterials for bone screws are being developed which have biodegradable properties so that post-operative bone healing is not required. The purpose of this study was to determine the effect of cantula fiber addition on tensile strength, wear rate, and crystallinity of nano-HA/magnesium/Shellac biocomposite for bone screw materials. Nano-HA/magnesium/Shellac/cantula fiber materials were mixed using a blender. The material was mixed with a magnesium/hydroxyapatite ratio of 70/30 and cantula fiber is added with variations of 0%, 10%, 20% and 30% of total volume. After that, the material mixture was compacted with a pressure of 300 MPa for 10 minutes. Then the sintering process was carried out at a temperature of 140 ̊C for two hours. The results showed that the highest tensile strength value was 7.86 MPa at 30% variation. The lowest wear rate was 0.31 x 10-3 mm3/Nm at 30% variation. The highhest crystallinity in XRD observations was obtained at 30% variation, which was 79.65%.
Analisys of Tensile Strength, Wear Rate, and Cristallinity of Biocomposite Nano-HA/Magnesium/Shellac Reinforced Cantula Fiber for Bone Screw Material Utami, Dea Pawestry; Triyono, Joko; Raharjo, Wijang Wisnu; Tritjahjono, Rachmad Imbang
Mekanika: Majalah Ilmiah Mekanika Vol 23, No 1 (2024): MEKANIKA: Majalah Ilmiah Mekanika
Publisher : Universitas Sebelas Maret

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20961/mekanika.v23i1.71127

Abstract

Accidents are a major cause of fractures in Indonesia. One of the treatments for fractures is bone screws with support plates that are placed on broken bone. Currently, many biomaterials for bone screws are being developed which have biodegradable properties so that post-operative bone healing is not required. The purpose of this study was to determine the effect of cantula fiber addition on tensile strength, wear rate, and crystallinity of nano-HA/magnesium/shellac bio-composite for bone screw materials. Nano-HA/magnesium/shellac/cantula fiber materials were mixed using a blender. The material was mixed with a magnesium/hydroxyapatite ratio of 70/30 and cantula fiber was added with variations of 0%, 10%, 20% and 30% of total volume. After that, material mixture was compacted with a pressure of 300 MPa for 10 minutes. Then sintering process was carried out at temperature of 140 °C for two hours. The results showed that the highest tensile strength value was 7.86 MPa at 30% variation. The lowest wear rate was 0.31 x 10-3 mm3/Nm at 30% variation. The highest crystallinity in X-Ray Diffraction observations was obtained at 30% variation, which was 79.65%.