Claim Missing Document
Check
Articles

Found 2 Documents
Search

Effect of the Addition of Sikacrete-W and Viscocrete-3115n on the Compressive Strength of Concrete in Waterlogged Bore Pile Casting Work Bunjamin, Abun; Pertiwi, Ayu Ningrum; Yudiana, Elpan; Makkih, Muhammad; Muzahab, Laode Azan
Journal of Social Research Vol. 4 No. 7 (2025): Journal of Social Research
Publisher : International Journal Labs

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55324/josr.v4i7.2693

Abstract

This study examines the effect of the addition of Sikacrete-W and Viscocrete-3115N additives on the compressive strength of concrete in waterlogged bore pile casting work. Concrete is an important construction material, but underground casting can lead to washout and segregation, which negatively impacts concrete quality. In this study, variations of Sikacrete-W addition of 3%, 5%, and 10% and 0.6% Viscocrete-3115N were used to improve the cohesion and viscosity of the mixture. The test results showed that the average compressive strength of concrete with the addition of additives was lower than that of normal concrete, with the largest decrease occurring in the 10% Sikacrete-W mixture. Meanwhile, a 5% Sikacrete-W mixture yielded an optimal compressive strength of 31.74 MPa, suggesting that the addition of additives could affect the characteristics of concrete under special conditions.
Peran Viskos Damper pada Struktur Gedung dengan Denah Beraturan dan Tak Beraturan Terhadap Beban Gempa Muzahab, Laode Azan; Zulkarnaen, Muhammad Rizky; Fafaro, Muhamad Ghulam; Sipayung, Yando Rolan; Pratama, Darma Putra Andika
Jurnal Impresi Indonesia Vol. 4 No. 8 (2025): Indonesian Impression Journal (JII)
Publisher : Riviera Publishing

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58344/jii.v4i8.6893

Abstract

Penelitian ini bertujuan untuk mengevaluasi efektivitas penggunaan fluid viscous damper (FVD) dalam meningkatkan kinerja seismik struktur gedung pada denah beraturan dan tidak beraturan. Dua model gedung beton bertulang enam lantai dimodelkan menggunakan perangkat lunak analisis dan desain struktur berdasarkan SNI 1726:2019 dan SNI 2847:2019. Analisis beban gempa dengan metode Respon Spektrum. FVD dipasang pada sisi luar setinggi gedung di kedua arah sumbu bangunan. Parameter yang diamati meliputi simpangan antar lantai (interstory drift), perpindahan lateral (story displacement), gaya geser tingkat (story shear), dan gaya geser dasar (base shear) dan kapasitas struktur terhadap beban gempa. Hasil analisis menunjukkan bahwa penggunaan FVD mampu mereduksi respons seismik secara signifikan pada kedua tipe gedung. Gedung beraturan menunjukkan distribusi beban yang lebih stabil, sedangkan gedung tidak beraturan memperoleh peningkatan performa yang lebih signifikan dengan FVD. Selain itu, kapasitas struktur meningkat setelah pemasangan FVD, yang menunjukkan kemampuan struktur menyerap energi lebih besar sebelum mengalami kerusakan plastis. Oleh karena itu, FVD direkomendasikan sebagai solusi efektif dalam desain maupun retrofit bangunan tahan gempa.