Claim Missing Document
Check
Articles

Found 1 Documents
Search

Analisis Pengaruh Penggunaan Jenis Detektor Gas Metana terhadap Akurasi dan Waktu Respon di PT. Pertamina Hulu Mahakam Samsul Anwar; Aulidina Dwi Nur Indriyanti
Jupiter: Publikasi Ilmu Keteknikan Industri, Teknik Elektro dan Informatika Vol. 3 No. 4 (2025): Juli: Publikasi Ilmu Keteknikan Industri, Teknik Elektro dan Informatika
Publisher : Asosiasi Riset Ilmu Teknik Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.61132/jupiter.v3i4.986

Abstract

Methane gas detection is crucial in the oil and gas sector to enhance safety and operational efficiency. This study examines the impact of three types of gas detectors—catalytic, infrared, and ultrasonic sensors—on accuracy and response time. The research was conducted at PT PHM's onshore and offshore sites to evaluate sensor performance in operational environments. A quantitative approach with direct field observation was used. Data were collected by measuring methane gas concentrations indicated by detectors, which were then compared to standard gas concentrations. Response times were recorded when the detectors were exposed to methane concentrations of 2.5% LEL until the alarm triggered at 40% of full scale. Data analysis was performed using descriptive statistics, homogeneity test, normality test, ANOVA, and post hoc tests. The results show that the infrared detector had a response time of 2.87 seconds with an accuracy of 0.218%. The catalytic detector had a response time of 8.91 seconds and accuracy of 0.489% and the ultrasonic detector had a response time of 6.15 seconds and accuracy of 0.842%. Overall, the infrared detector demonstrated the best performance in response time and is recommended for use at PT PHM.