Haryanto, Edy
Jurusan Teknologi Laboratorium Medis, Poltekkes Kemenkes Suarabaya, Surabaya

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

Keterkaitan Jumlah Trombosit dengan Imunoglobulin G dan Jumlah Lekosit dengan Imunoglobulin M pada Kasus Demam Berdarah Dengue Yunarsih, Yunarsih; Haryanto, Edy; Rahayuningsih, Christ Kartika
Jurnal Penelitian Kesehatan SUARA FORIKES Vol 16, No 3 (2025): Juli-September 2025
Publisher : FORIKES

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33846/sf16320

Abstract

Dengue hemorrhagic fever is a disease caused by the dengue virus that is increasing in various regions, with one of the signs being thrombocytopenia. The purpose of this study was to analyze the relationship between platelet and leukocyte counts with dengue Immunoglobulin G and Immunoglobulin M examinations. This study design was cross-sectional, involving 31 patients at Parang Health Center, Lembeyan Health Center, and Ngariboyo Health Center in Magetan Regency. Blood tests were performed using a hematology analyzer with the volumetric impedance method and rapid immunochromatography test. The examination data were analyzed using the Spearman correlation test. The results of the analysis showed that the average platelet count was 72,709 / µL, the average leukocyte count was 3,685 / µL, positive Immunoglobulin G was 45.2%, positive Immunoglobulin M was 19.4%, while positive Immunoglobulin G and Immunoglobulin M were 35.5%. Meanwhile, the p-value of less than 0.05 was in the correlation between the number of platelets with Immunoglobulin G and the correlation between the number of leukocytes with Immunoglobulin M. Meanwhile, the p-value >0.05 was obtained in the correlation between the number of platelets with Immunoglobulin M and the correlation between the number of leukocytes with Immunoglobulin G. Thus, it could be concluded that in dengue hemorrhagic fever patients, Immunoglobulin G is related to the number of platelets, while Immunoglobulin M is related to the number of leukocytes.Keywords: dengue hemorrhagic fever; platelets; leukocytes; Immunoglobulin G; Immunoglobulin M ABSTRAK Demam berdarah dengue merupakan penyakit yang disebabkan oleh virus dengue mengalami peningkatan di berbagai wilayah, dengan salah satu tanda yaitu trombositopenia. Tujuan penelitian ini adalah untuk menganalisis hubungan antara jumlah trombosit dan lekosit dengan pemeriksaan Immunoglobulin G dan Immunoglobulin M dengue. Rancangan penelitian ini adalah cross-sectional, yang melibatkan 31 pasien di Puskesmas Parang, Puskesmas Lembeyan dan Puskesmas Ngariboyo Kabupaten Magetan. Pemeriksaan darah dilakukan menggunakan hematology analyzer dengan metode volumetric impedance dan rapid test immunochromatography. Data hasil pemeriksaan dianalisis dengan uji korelasi Spearman. Hasil analisis menunjukkan bahwa rerata jumlah trombosit adalah 72.709 /uL, rerata jumlah lekosit adalah 3.685 /uL, Immunoglobulin G positif adalah 45,2%, Immunoglobulin M positif adalah 19,4%, sedangkan Immunoglobulin G dan Immunoglobulin M positif adalah 35,5%. Sementara itu nilai p kurang dari 0,05 adalah pada korelasi antara jumlah trombosit dengan Immunoglobulin G dan korelasi antara jumlah lekosit dengan Immunoglobulin M. Sementara itu, nilai p >0,05 didapatkan pada korelasi antara jumlah trombosit dengan Immunoglobulin M dan korelasi antara jumlah lekosit dengan Immunoglobulin G. Dengan demikian dapat disimpulkan bahwa pada penderita demam berdarah dengue, Immunoglobulin G berkaitan dengan jumlah trombosit, sedangkan Immunoglobulin M berkaitan dengan jumlah lekosit.Kata kunci: demam berdarah dengue; trombosit; lekosit; Immunoglobulin G; Immunoglobulin M
Glucose Oxidase–Peroxidase Aminoantipyrine Sebagai Metode Pemeriksaan Glukosa yang Akurat Terhadap Heksokinase pada Pasien Diabetes Mellitus Tipe 2 Pangesti, Rice Kusuma; Haryanto, Edy; Puspitasari, Ayu
Jurnal Penelitian Kesehatan SUARA FORIKES Vol 16, No 3 (2025): Juli-September 2025
Publisher : FORIKES

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33846/sf16319

Abstract

Diabetes mellitus is a chronic disease characterized by high blood glucose levels. The number of diabetes mellitus patients is increasing day by day, thus increasing the need for blood glucose testing. This test is commonly used as an initial screening to detect diabetes mellitus. Among the methods for measuring blood glucose levels are Point of Care Testing (POCT), Glucose Oxidase-Peroxidase Aminoantipyrine (GOD PAP), and hexokinase. This study aimed to analyze the differences and accuracy of blood glucose test results using the POCT and GOD PAP methods against hexokinase in patients with type 2 diabetes mellitus. This study was an observational, correlational analytic study, involving 33 patients with type 2 diabetes mellitus selected by purposive sampling method. Blood glucose levels were examined using the POCT, GOD PAP, and hexokinase methods. The POCT-based glucose test results had a bias value (d%) of 34.52% and a recovery value of 86.32%, indicating a significant deviation from hexokinase. In contrast, the GOD-PAP-based glucose test results had a bias value of 4.27 and a recovery value of 102%, meaning they were still within the acceptable range. A t-test showed no significant difference between POCT and GOD-PAP results for hexokinase. Furthermore, it was concluded that the GOD-PAP method is accurate for blood glucose testing in patients with type 2 diabetes mellitus.Keywords: accuracy; blood glucose; Point of Care Testing (POCT), Glucose Oxidase-Peroxidase Aminoantipyrine (GOD-PAP), hexokinase; type 2 diabetes mellitus ABSTRAK Diabetes melitus adalah penyakit kronis yang ditandai dengan tingginya kadar glukosa pada darah. Pasien diabetes melitus semakin hari meningkat, maka kebutuhan pemeriksaan kadar glukosa darah meningkat. Pemeriksaan ini umum digunakan sebagai skrining awal untuk mendeteksi diabetes melitus. Di antara metode pengukuran kadar glukosa darah adalah Point of Care Testing (POCT), Glucose Oxidase-Perokxidase Aminoantipyrine (GOD PAP) serta heksokinase. Penelitian ini bertujuan untuk menganalisis perbedaan dan akurasi hasil pemeriksaan glukosa darah menggunakan metode POCT dan GOD PAP terhadap heksokinase pada pasien diabetes melitus tipe 2. Penelitian ini termasuk jenis observasional analitik korelasional, dengan melibatkan 33 pasien diabetes mellitus tipe 2 yang dipilih dengan metode purposive sampling. Pemeriksaan kadar glukosa darah dilakukan menggunakan metode POCT, GOD PAP dan heksokinase. Hasil pemeriksaan glukosa berbasis POCT memiliki nilai bias (d%) adalah 34,52% dan nilai recovery adalah 86,32%, berarti menyimpang cukup besar dari heksokinase. Sebaliknya, hasil pemeriksaan glukosa berbasis GOD-PAP memiliki nilai bias adalah 4,27 dan nilai recovery adalah 102%, berarti masih berada dalam rentang yang dapat diterima. Berdasarkan uji t, perbedaan hasil POCT dan GOD PAP terhadap heksokinase adalah tidak signifikan. Selanjutnya disimpulkan bahwa metode GOD PAP adalah akurat dalam pemeriksaan glukosa darah pasien diabetes mellitus tipe 2.Kata kunci: akurasi; glukosa darah; Point Of Care Testing (POCT), Glucose Oxidase-Perokxidase Aminoantipyrine (GOD PAP), heksokinase; diabetes mellitus tipe 2