The Influence of Hydrogen Flow Rate and Humidifier Temperature on Performance of a PEMFC with Ti-Co/C Catalyst Adhiyanti, Nurmalina; Rohendi, Dedi; Utama, Muhammad Prima; Syarif, Nirwan; Rachmat, Addy; Yulianti, Dwi Hawa; Normah, Normah
IJFAC (Indonesian Journal of Fundamental and Applied Chemistry) Vol 10, No 3 (2025): October 2025
Publisher : IJFAC (Indonesian Journal of Fundamental and Applied Chemistry)

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

This study explores the effect of hydrogen flow rate and humidifier temperature on the performance of the Membrane Electrode Assembly (MEA) using Ti-Co/C catalyst at the cathode and Pt/C at the anode in a single-cell Proton Exchange Membrane Fuel Cell (PEMFC). MEAs were fabricated by the spraying method and characterized using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) to determine their electrochemical surface area (ECSA) and conductivity. The results showed that the optimized ECSA value reached 8.38 cm2/g, and the electrical conductivity was 3.76 × 10-8 S/cm. The best performance was achieved at a hydrogen flow rate of 100 mL/min and room temperature humidification. Under the hydrogen flow rate test, the maximum power density reached 0.364 mW/cm2, while in the humidifier temperature variation, a maximum power density of 0.375 mW/cm2  was obtained at a current density 2.4 mA/cm2. These findings suggest that Ti-Co/C is a promising low-cost catalyst alternative to Pt and that operational conditions play a critical role in MEA performance