Transmission line fault detection using empirical mode decomposition in presence of wind intermittency Bokka, Venkata Krishna; Biju, E. R.; Mortha, Sai Veerraju; Mahammad, Majahar Hussain; Irshad, Shaik Mohammad
International Journal of Applied Power Engineering (IJAPE) Vol 14, No 4: December 2025
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijape.v14.i4.pp960-969

Abstract

The regular fault detection approaches are failed to detect the faults in wind integrated transmission networks due to intermittency nature of the wind energy. More reliable schemes are required to accomplish the detection of faults in presence wind. This article proposed empirical mode decomposition (EMD) based fault detection scheme to detect various faults in wind integrated transmission lines during the normal and stressed conditions of the system. The instantaneous current measurements available at either sending or receiving end are processed through EMD to decompose it into a series of intrinsic mode functions (IMFs) and IMF2 is identified as a dominated IMF with numerous case wise investigations. 1/4th cycle moving window is used to calculate the absolute sum of the IMF2 coefficients to detect the faults with the support of a predefined threshold. The efficacy of the method is tested on different types of faults during the normal condition in presence of wind and later extended to stressed conditions such as power swing. The method is reliable during the typical cases and includes remote end and high resistance faults. All the experiments are carried out in Simulink to generate the measurement data and programs are executed in MATLAB.
Frequency control of hybrid power system with fractional order secondary controller using improved biogeography-based krill herd algorithm Kumar, Kukkamalla Kiran; Balaji, Gobinathan; Pedakota, Kanta Rao; Mahammad, Majahar Hussain; Suraya, Syed
International Journal of Applied Power Engineering (IJAPE) Vol 14, No 4: December 2025
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijape.v14.i4.pp816-825

Abstract

To meet the demand of electrical power, structural changes of the power system from the generation side are necessary by integrating the renewable sources into the existing system. In the presence of renewables, the active power imbalances caused by both generation and demand are reduced with the classical units (like thermal) since the wind speed and irradiance (inputs of wind and solar plants) are volatile and nonlinear in nature. The frequency deviations triggered by such active power imbalances of the hybrid power system integrated with both conventional and renewable energy plants are minimized with better secondary control schemes. Therefore, this article suggests fractional order secondary controller (FOSC) for conventional units of the interconnected power system to strengthen the frequency stability of the system during the demand perturbations. The optimal gains of the FOSC are identified with an improved biogeography-based krill herd optimizer with the help of the performance indicator integral square error. To elevate the improvements of FOSC, comparisons are provided with classical controllers during the simple, random load perturbations with and without generation changes. Furthermore, sensitivity analysis on system parameters is performed to show the robustness of the FOSC over classical control strategies.