The Effect of Tube Current Variations on Cranium Radiograph Images Using the MATLAB Program Nurul Auliyaa Hasbi; Asmiati Amir; Muhammad Yunus; Nurul Jannah Jamal; Nurbeti Salam; Muh. Rusli
Jurnal Penelitian Pendidikan IPA Vol 11 No 11 (2025): November
Publisher : Postgraduate, University of Mataram

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29303/jppipa.v11i11.13042

Abstract

Matrix Laboratory (MATLAB) is a software based on matrices, which is easy to use for solving various mathematical and computing problems. This study aimed to determine how variations in tube current (mA) affect the radiographic image of the cranium using the MATLAB program and to assess the program's quantification of this effect. The sample in this study consisted of 3 volunteers who performed AP projection cranial radiography examinations with varying tube current at Pelamonia TK. II Hospital, Makassar. Each sample had the same treatment in patient preparation, examination position, examination projection, and the same exposure factor value, which differed only in the use of tube current values, ​​where the volunteer 1 with 200 mA, the volunteer 2 with 250 mA and volunteer 3 with 320 mA. Measurement of the quality of the AP projection cranium image with tube current of 200 mA, the percentage was 96.11%. At 250 mA, the percentage was 95.00%; at 320 mA, it dropped to 92.78%. It was determined that the optimal tube current variation was 200 mA with the highest percentage in measuring the image quality (density, contrast, sharpness, and detail) of the AP projection Cranium against variations in tube current is almost perfect.
PENGARUH VARIASI TEGANGAN TABUNG PADA INFORMASI ANATOMI RADIOGRAFI CRANIUM PROYEKSI LATERAL DENGAN MENGGUNAKAN PROCESSING DIGITAL RADIOGRAPHY nurul auliyaa hasbi; Datu Euphratadhi Pradana; Wahdini Hanifah
Journal of Hospital Administration and Management (JHAM) Vol 7 No 1 (2026): Journal of Hospital Administration and Management (JHAM)
Publisher : LPPM Universitas Awal Bros

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.54973/jham.v7i1.906

Abstract

Almost all hospitals use radiology aircraft that have an automatic exposure factor system, including in the regulation of tube voltage. However, the value of the automatic exposure factor is not adjusted to the patient's condition or the thickness of the object. Since the tension linkage of the tube does not correspond to the thickness of the object, research must be carried out to optimize the tension value of the tube according to the anatomical data collected. This study aimed to determine how the variation in tube tension affects the anatomical information on lateral projection cranium radiography. Knowing the value of the tube voltage used to best show anatomical information, radiography, radiography, cranium, lateral projection, and relationship to each other. The place this research is RSKD Dadi, Makassar. This research was carried out through a quantitative method with an experimental approach. The research tool collected data through observation and questionnaires. Radiography results of lateral projection cranium examination with kV variation. Data analysis was carried out using the SPSS test. The results showed that the ideal tube voltage value to use was 75 kV, with the highest average values of 7.63, 6.00 for 80 kV and 4.72 for 85 kV. The test results showed that the three cranial radiographies had different qualities. The significance value is 0.000 less than 0.05. The use of good tube voltage to use based on the questionnaire is 75 kV, because it can show the quality of clear anatomical details so that it is easy to analyze.