This Author published in this journals
All Journal Atom Indonesia
Tahiri, N.
Unknown Affiliation

Published : 1 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 1 Documents
Search

Monte Carlo Simulation of Pediatric Chest Radiography: Validation of the Irradose Through Comparison with MCNP Qassimi, O.; Kabach, O.; Messous, M. Y.; Tahiri, N.; Arianto, F.; El Bounagui, O.
Atom Indonesia Vol 52, No 1 (2026): APRIL 2026
Publisher : National Research and Innovation Agency

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55981/aij.2026.1763

Abstract

Radiological examinations are essential for medical diagnostics, but accurate estimation of dose deposition is crucial for patient safety, particularly in pediatric patients. This study employs Monte Carlo simulations with the MCNP code and a newly developed custom program, Irradose, to analyze photon dose deposition in a cylindrical phantom representing the thorax of a 10-year-old child. Two tissue-equivalent compositions were modeled: water and a more realistic HCNO-based soft tissue mixture. Depth-dose distributions obtained with Irradose were compared to MCNP results. Both codes predicted a maximum dose at 2 cm depth, followed by exponential fall-off, with deviations remaining below 5% across the depth range. These results validate Irradose as a reliable and computationally efficient tool for pediatric chest dosimetry in phantom studies. While limited to simplified geometries, this work demonstrates the potential of Irradose for use in preliminary dose assessments and as a complement to established Monte Carlo codes.