Jurnal Energi Dan Manufaktur
Vol 5, No.1 April 2011

Studi Eksperimental Tentang Head Loss Pada Aliran Fluida Yang Melalui Elbow 90°

Helmizar - (Unknown)



Article Info

Publish Date
08 Nov 2012

Abstract

Factors that cause energy loss in a piping system is something that is interesting and important to be studied moredeeply. 90° Elbow is a common connection in piping systems. Elbow 90° contributes to the incidence of head loss. Thisresearch will try to identify the influence of curvature (R/d) to the head lossThis study uses test model 90 ° elbows connection with the variation of the radius of curvature of the connectionelbow 90 ° to the pipe diameter (R / d) of 4.199 and 6.299. Flow rates are varied with Q1 = 0.000312345986 m3/s and Q2 =0.000265776 m3/s.The experimental results show that the R/d = 6.299 have a greater head loss rather than the R/d = 4.199. Strikingdifferences in the distribution of pressure coefficient between the radius of inner and outer radius. favorable pressuregradient phenomena occur on the inner radius. Events adverse pressure gradient at the outer radius of elbow allegedlycontributing to the loss of energy / head loss at the elbow 90 °.

Copyrights © 2011






Journal Info

Abbrev

jem

Publisher

Subject

Energy Industrial & Manufacturing Engineering

Description

"Jurnal Energi dan Manufaktur" is a journal published by Department of Mechanical Engineering, University of Udayana, Bali since 2006. During 2006-2011 the journal's name was "Jurnal Ilmiah Teknik Mesin CAKRAM" (Scientific journal in mechanical engineering, CAKRAM). "Jurnal Energi dan Manufaktur" is ...