BERKALA FISIKA
Vol 11, No 4 (2008): Berkala Fisika

PENGARUH FAKTOR EKSPOSI PADA PEMERIKASAAN ABDOMEN TERHADAP KUALITAS RADIOGRAF DAN PAPARAN RADIASI MENGGUNAKAN COMPUTED RADIOGRAPHY

Fahmi, Arif (Unknown)
Firdausi, K. Sofjan (Unknown)
Setia Budi, Wahyu (Unknown)



Article Info

Publish Date
30 Mar 2012

Abstract

It has been researched about the change of exposure factors in radiographic examination of abdomen to radiographic quality and radiation exposure using computed radiography. The change of exposure factors to radiographic quality is obtained by measurement of radiographic density, which transmitted to step wedges and phantom abdomen. The density difference of step wedge and abdomen at each change of exposure factors result in radiographic contrast. To obtain radiation dose for patients, it is accounted by analytic method. The affect of scattering rate dose is obtained by measurement of scattering exposure rate using survey meter with positioned 100 cm from the object. The result of experiment shows that change of exposure factors in radiographic examination of abdomen makes no significant difference between radiographic density and contrast; however, it has decreased the patient dose. Keywords: radiation exposure, radiographic density and contrast

Copyrights © 2008






Journal Info

Abbrev

berkala_fisika

Publisher

Subject

Physics

Description

BERKALA FISIKA adalah jurnal saintifik yang diterbitkan secara periodik 3 bulanan. Jurnal ini memuat kajian-kajian Fisika baik kajian teoretik maupun hasil eksperimen. Jurnal ini juga memberi ruang yang luas bagi kajian – kajian aplikasi fisika dalam bidang teknologi, ilmu-ilmu hayati dan ...