Jurnal Teknik Mesin
Vol 10, No 1 (2020)

The Effect of Rambutan’s Leaf Extract Inhibitor on Corrosion Rate on Cast Iron Block Car Sedan Nissan in HCl Solution 1%

Ismet Eka Putra (Institut Teknologi Padang)
Pren Tanjung (Institut Teknologi Padang)



Article Info

Publish Date
30 Apr 2020

Abstract

Corrosion in cast iron can be overcome by rambutan counter measures (Nepheliumlappaceum L.). The object of the study which is placed in 1% HCl solution each of 3 specimens in 1 vessel. 12 specimens in 4 vessels. In this study, soaking iron cast iron car block Sedan Nissan without inhibitor and the variation of inhibitor 5%, 10%, and 15% with immersion time 5, 10, and 15 days. The solution is coincides with 0.095 m3/hr of passage in a vessel with a volume of 1% 900 ml of HCl. The highest corrosion rate in cast iron soaked in 1% HCl without using rambutan leaf extract and immersion time of 15 days is 0,075054 mpy. The lowest corrosion rate in cast iron soaked in 1% HCl solution using 15% rambutan leaf extract and a 15 day immersion time of 0,025863 mpy.

Copyrights © 2020






Journal Info

Abbrev

tmesin

Publisher

Subject

Mechanical Engineering

Description

Jurnal Teknik Mesin (JTM) is a journal aims to be a peer-reviewed platform and an authoritative source of information. We publish original research papers, review articles and case studies focused on mechanical engineering and other related topics. All papers are peer-reviewed by at least two ...