Atom Indonesia Journal
Vol 47, No 2 (2021): August 2021

Comparisons of Water-Equivalent Diameter Measured on Images of Abdominal Routine Computed Tomography with and without A Contrast Agent

A. Nitasari (Department of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Jl. Prof. Soedarto SH, Tembalang, Semarang 50275, Indonesia)
C. Anam (Department of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Jl. Prof. Soedarto SH, Tembalang, Semarang 50275, Indonesia)
W. S. Budi (Department of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Jl. Prof. Soedarto SH, Tembalang, Semarang 50275, Indonesia)
A. L. Wati (Department of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Jl. Prof. Soedarto SH, Tembalang, Semarang 50275, Indonesia)
S Syarifudin (Department of Radiology, Dr. Kariadi Hospital, Jl. Dr. Sutomo No.19, Semarang Selatan, Semarang 50244, Indonesia)
G. Dougherty (Department of Applied Physics and Medical Imaging, California State University Channel Islands, Camarillo, CA, USA)



Article Info

Publish Date
09 Aug 2021

Abstract

The size-specific dose estimate (SSDE) is a metric for an estimation of patient dose in computed tomography (CT). The SSDE strongly depends on the       water-equivalent diameter (DW). In abdominal CT examinations, a contrast agent is sometimes used to more clearly visualize tissue lesions. The Hounsfield unit (HU) of CT images with and without the use of a contrast agent at specific areas is slightly different and it may affect the DW value. This study aimed to compare the DW values calculated from axial CT images in patients who had undergone routine abdominal scans both with and without the use of a contrast agent. Axial images of 144 patients with a weight range of 3.5 kg to 90 kg who had undergone routine abdominal scans both with and without the use of a contrast agent using a Siemens Sensation 64 CT scanner were retrospectively collected. The DW values were automatically calculated using the Matlab-based IndoseCT (version 15a) software. The results show the percentage difference between DW,contrast and DW,non-contrast is below 2 %.As a result, the mean SSDEcontrast is 1.5 % smaller than SSDEnon-contrast. Due to the effect of a contrast agent on the DW and SSDE values is below 2 %, the axial images of CT abdomen without the use of a contrast agent can be used as the accurate estimation of DW and SSDE for images with the use of a contrast agent.

Copyrights © 2021






Journal Info

Abbrev

aij

Publisher

Subject

Materials Science & Nanotechnology

Description

Exist for publishing the results of research and development in nuclear science and technology Starting for 2010 Atom Indonesia published three times a year in April, August, and December The scope of this journal covers experimental and analytical research in all areas of nuclear science and ...