An Automated Measurement of Image Slice Thickness of Computed Tomography S. Sofiyatun; C. Anam; U. M. Zahro; D. A. Rukmana; G. Dougherty
Atom Indonesia Vol 47, No 2 (2021): August 2021
Publisher : PPIKSN-BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.17146/aij.2021.1111

Abstract

Measurement of the slice thickness in computed tomography (CT) is usually made using a special phantom, such as the AAPM CT performance phantom. Images of the phantom are analyzed manually and subjectively. The purpose of this study is to develop an automated system for measuring the slice thickness of the CT image of the phantom using MATLAB software.The CT AAPM performance phantom was scanned by a 128 multi-slice computed tomography scanner (Revolution Evo, GE Healthcare, Waukesha, WI) at a slice thickness of 5 mm with four different phantom orientations and also scanned by a 6 multi-slice CT scanner (Somatom Emotion 6, Siemens AG, Forchheim, Germany) for two slice thicknesses of 5 and 10 mm. Our automatedmethod produced an accurateslice thickness value less than 0.5 mm different from the nominal slice thicknesses and manual measurements. Similar results were obtained when the phantom was rotated. This system is more objective and effective compared to manual systems.
Comparisons of Water-Equivalent Diameter Measured on Images of Abdominal Routine Computed Tomography with and without A Contrast Agent A. Nitasari; C. Anam; W. S. Budi; A. L. Wati; S Syarifudin; G. Dougherty
Atom Indonesia Vol 47, No 2 (2021): August 2021
Publisher : PPIKSN-BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.17146/aij.2021.1112

Abstract

The size-specific dose estimate (SSDE) is a metric for an estimation of patient dose in computed tomography (CT). The SSDE strongly depends on the       water-equivalent diameter (DW). In abdominal CT examinations, a contrast agent is sometimes used to more clearly visualize tissue lesions. The Hounsfield unit (HU) of CT images with and without the use of a contrast agent at specific areas is slightly different and it may affect the DW value. This study aimed to compare the DW values calculated from axial CT images in patients who had undergone routine abdominal scans both with and without the use of a contrast agent. Axial images of 144 patients with a weight range of 3.5 kg to 90 kg who had undergone routine abdominal scans both with and without the use of a contrast agent using a Siemens Sensation 64 CT scanner were retrospectively collected. The DW values were automatically calculated using the Matlab-based IndoseCT (version 15a) software. The results show the percentage difference between DW,contrast and DW,non-contrast is below 2 %.As a result, the mean SSDEcontrast is 1.5 % smaller than SSDEnon-contrast. Due to the effect of a contrast agent on the DW and SSDE values is below 2 %, the axial images of CT abdomen without the use of a contrast agent can be used as the accurate estimation of DW and SSDE for images with the use of a contrast agent.