RANCANGAN SISTEM MONITORING SUHU DAN KELEMBAPAN RUANG SERVER BERBASIS INTERNET OF THINGS

Emanuel Budi Raharjo (Akademi Teknologi Warga Surakarta)
Stefanus Marwanto (Akademi Teknologi Warga Surakarta)
Alfian Romadhona (Akademi Teknologi Warga Surakarta)



Article Info

Publish Date
02 Sep 2019

Abstract

Suhu dan kelembapan ruang server perlu dijaga sesuai dengan standar untuk menjamin server tidak mengalami gangguan atau kerusakan. Untuk mengetahui adanya permasalahan pada kondisi lingkungan dan mengantisipasinya lebih cepat maka faktor suhu dan kelembapan ruang server perlu dimonitor secara real time. Tujuan penelitian ini adalah membuat sistem monitoring suhu dan kelembapan ruang server secara real time yang hasilnya dapat diakses secara offline maupun online dengan memanfaatkan teknologi Internet of Things (IoT) berbasis modul NodeMCU ESP8266 dan sensor DHT11. NodeMCU ESP8266 dalam sistem monitoring berperan sebagai pengendali utama dengan tugas membaca data suhu dan kelembapan dari sensor DHT11 dan mengirimkannya ke penampil LCD karakter maupun ThingSpeak melalui koneksi jaringan internet wireless. Data akuisisi suhu dan kelembapan diambil secara kontinyu setiap jeda satu menit untuk selanjutnya dibandingkan dengan hasil pembacaan perangkat ukur standar Hygrometer HTC-1 guna mengetahui tingkat kesalahan rata-ratanya. Berdasarkan hasil penelitian diperoleh rata-rata kesalahan pembacaan suhu ruang server sebesar 2,0°C dan kelembapannya 3,1%RH. ABSTRACT The stable and reliable server operation is achieved by maintaining the server room’s humidity and temperature according to standards. Using a real-time monitoring system to record the two factors will ensure future error identification and give better anticipation. In this work real-time server room’s humidity and temperature monitoring system is designed to be accessible both online and offline using Node MCU ESP8266, DHT11, character LCD Display and Thing Speak. DHT11 sensor data are displayed in LCD while simultaneously transferred to the Thing Speak server through the wireless internet connection by Node MCU ESP8266. Acquisition data is sampled continuously in a one-minute sample rate for ten minutes and then recorded and compared with the standard Hygrometer HTC-1 to obtain the reading error rate of humidity and temperature. The result shows 2,3°C and 3,3%RH error rate for the server room’s temperature and humidity readings.

Copyrights © 2019






Journal Info

Abbrev

jte

Publisher

Subject

Automotive Engineering Chemical Engineering, Chemistry & Bioengineering Electrical & Electronics Engineering Industrial & Manufacturing Engineering Mechanical Engineering

Description

Jurnal Teknika merupakan jurnal ilmiah yang menyajikan artikel orisinal tentang pengetahuan dan informasi riset atau aplikasi riset dan pengembangan terkini dalam bidang teknologi. Ruang lingkup Jurnal Teknika meliputi Teknik Mesin, Teknik Elektro, Sistem Informasi, Teknik Industri dan Kimia ...