PA Fan (Primary air fan) is equipment that functions to suck air from the atmosphere which aims to supply air to the coal pulveriser to dry the coal and transfer the coal ash to the boiler. PA Fan in operation has tripped with an indication on the protection panel OP_ROC. This ROC indication appears due to an indication of a short circuit to ground or an imbalance of currents between phases which causes a zero connection current. When the local inspection was carried out, it was found that there was a burnt insulator on the S side phase. This resulted in the motor losing one phase and causing ROC (Residual Over Current) protection on the 6 kV protection module to work.

Copyrights © 2022






Journal Info

Abbrev

birex

Publisher

Subject

Agriculture, Biological Sciences & Forestry Biochemistry, Genetics & Molecular Biology Civil Engineering, Building, Construction & Architecture Physics Transportation

Description

Budapest International Research in Exact Sciences (BirEx-Journal) is a peer reviewed journal published in January, April, July, October welcome research paper in Medical Science, Agriculture Science, Biological Science, Engineering Science and other related areas and it is published in both online ...