The Journal of Pure and Applied Chemistry Research
Vol 3, No 1 (2014)

Construction and Characterization of Coated Wire Oxalate Ion Selective Electrode Based on Chitosan

Zuri Rismiarti (Brawijaya University)
Atikah Atikah (Brawijaya University)
Hermin Sulistyarti (Brawijaya University)



Article Info

Publish Date
09 Dec 2013

Abstract

PVC (polyvinyl chloride) membrane based coated wire oxalate ion selective electrode has been developed by using chitosan. The results showed the optimum composition of the membrane was chitosan: aliquat 336: PVC: DBP = 4:1:33:62 (% weight). The electrode showed Nernstian response, Nernst factor 29.90 mV/decade of concentration, linier concentration range of 1x10-5 - 1x10-1 M, detection limit of 2.56 x10-6 M, response time of 30 second, and life time of 42 days. ISE’s performance worked well in pH range of 5-7 and temperature of 25-50 oC. Validation test showed no significant difference (t test) with the SSA method so that the potentiometric method could be used as an alternative method for determining urinary oxalate.

Copyrights © 2014






Journal Info

Abbrev

jpacr

Publisher

Subject

Chemical Engineering, Chemistry & Bioengineering Chemistry Materials Science & Nanotechnology Medicine & Pharmacology

Description

The Journal of Pure and Applied Chemistry Research focuses in publishing research articles in the field of Chemistry and Applied Chemistry. The target is in exploring, investigating, and developing chemicals sources from local and/or Indonesian to increase the value. Scope of the journal is organic ...