Pengaruh Air Laut terhadap Kapasitas Beban pada Balok Beton Bertulang yang Diperkuat GFRP-S dengan Perendaman selama Satu Tahun

Asri Mulya Setiawan (Universitas Fajar, Makassar)
Erniati Bachtiar (Universitas Fajar, Makassar)



Article Info

Publish Date
01 Oct 2018

Abstract

The test results on specimens without GFRP-S reinforcement showed that there was a decrease in load capacity for BN0 specimens of 1.383%. Decrease in BN6 test material capacity after soaking sea water for 6 months. Whereas for specimens with reinforcement of GFRP-S shows a decrease in maximum load on BF6 and BF12 specimens against BF0 test objects. The percentage of decrease in loads is 3.898% and 4.285%, respectively. Decreased load capacity of BF12 specimens after 12 months of seawater immersion. This is due to a decrease in the capacity of the bond on the GFRP along with the soaking time, thus accelerating the occurrence of debonding.

Copyrights © 2018