Jurnal Rekayasa Proses
Vol 5 No 1 (2011): Volume 5, Number 1, 2011

Analisis eksperimental fluks kalor pada celah sempit anulus berdasarkan variasi suhu air pendingin menggunakan bagian uji HeaTiNG-01

Bambang Riyono (Badan Pengawas Tenaga Nuklir – BAPETEN Jl. Gajah Mada No. 8 - Jakarta)
Indarto Indarto (Jurusan Teknik Mesin dan Industri, Fakultas Teknik – Universitas Gadjah Mada, Jl. Grafika No.2, Jogjakarta 55281)
Sinta Tri Habsari (Badan Pengawas Tenaga Nuklir – BAPETEN Jl. Gajah Mada No. 8 - Jakarta)
Mulya Juarsa (Departemen Teknik Mesin Fakultas Teknik, Universitas Indonesia, Kampus UI, Depok 16424)
Kiswanta Kiswanta (Laboratorium Termohidrolika Eksperimental BOFA PTRKN BATAN Gd. 80 Kawasan PUSPIPTEK Serpong-Tangerang15310)
Ainur R. (Laboratorium Termohidrolika Eksperimental BOFA PTRKN BATAN Gd. 80 Kawasan PUSPIPTEK Serpong-Tangerang15310)
Edy S. (Laboratorium Termohidrolika Eksperimental BOFA PTRKN BATAN Gd. 80 Kawasan PUSPIPTEK Serpong-Tangerang15310)
Joko P. W. (Laboratorium Termohidrolika Eksperimental BOFA PTRKN BATAN Gd. 80 Kawasan PUSPIPTEK Serpong-Tangerang15310)
Ismu H. (Laboratorium Termohidrolika Eksperimental BOFA PTRKN BATAN Gd. 80 Kawasan PUSPIPTEK Serpong-Tangerang15310)



Article Info

Publish Date
30 Jun 2011

Abstract

Experiment to investigate the mechanism of boiling heat transfer in a narrow gap on severe accident scenarios of TMI-2 nuclear power plant is necessary to develop the understanding of the related accident management.The present study aimed to obtain heat flux value and critical heat flux (CHF) during boiling heat transfer process in a narrow gap of annulus. The study was experimentally carried out using the HeaTiNG 01 test with water as cooling fluid which temperature was varied at 75°C, 85°C dan 95°C. The rod was heated to 650°C. The boiling process during cooling was investigated by recording the transient temperature of the heated rod. The data was used to calculate the heat flux and wall superheat which results were represented in a boiling curve. The experimental results showed that the CHF value of the cooling media at 75°C was lower compared with that of at 85°C and 95°C. It was found that the values of CHF at 85°C and 95°C were close. The maximum CHF value at 75°C was 230 kW/m2 , while at 95°C was 282 kW/m2 . The CHF values at various position of heated rod was found to follow polynomial correlation. By comparing the boiling film areas from experimental results with that of Bromley correlation, it was concluded that boiling process in a narrow gap could not categorized as pool boiling process

Copyrights © 2011






Journal Info

Abbrev

jrekpros

Publisher

Subject

Chemical Engineering, Chemistry & Bioengineering

Description

Jurnal Rekayasa Proses is an open-access journal published by Chemical Engineering Department, Faculty of Engineering, Universitas Gadjah Mada as scientific journal to accommodate current topics related to chemical and biochemical process exploration and optimization which covers multi scale ...