Jurnal Nasional Teknik Elektro dan Teknologi Informasi
Vol 13 No 4: November 2024

Analisis Keandalan Sistem Distribusi Tenaga Listrik 20 kV pada Penyulang CWRU

Tasma Sucita (Program Study of Electrical Engineering Education, Faculty of Engineering and Industrial Education, Universitas Pendidikan Indonesia, Bandung 40154, Indonesia)
Maman Somantri (Program Study of Electrical Engineering Education, Faculty of Engineering and Industrial Education, Universitas Pendidikan Indonesia, Bandung 40154, Indonesia)
Diki Fahrizal (Program Study of Electrical Engineering Education, Faculty of Engineering and Industrial Education, Universitas Pendidikan Indonesia, Bandung 40154, Indonesia)
Mia Agista (Program Study of Electrical Engineering Education, Faculty of Engineering and Industrial Education, Universitas Pendidikan Indonesia, Bandung 40154, Indonesia)



Article Info

Publish Date
28 Nov 2024

Abstract

The electricity demand continues to rise alongside population growth, making the reliable distribution of electrical energy to consumers essential. The reliability of the 20 kV electricity distribution system on the CWRU feeder at the National Electricity Company (Perusahaan Listrik Negara, PT PLN) Customer Service Unit (Unit Layanan Pelanggan, ULP) Pelabuhan Ratu Area Surade was evaluated. The primary purpose was to analyze key reliability indices such as system average interruption frequency index (SAIFI), system average interruption duration index (SAIDI), customer average interruption duration index (CAIDI), average service availability index (ASAI), and average service unavailability index (ASUI), and to assess the economic impact of disruptions on consumers. Methodologies involved collecting and analyzing field data from PT PLN (Persero) ULP Pelabuhan Ratu’s CWRU feeder, utilizing quantitative reliability calculations and qualitative observations to identify internal and external factors affecting system reliability. The results showed that the SAIFI value reached 52.077 times/customer/year, and the SAIDI value was 99.400 hours/customer/year, classifying the system as unreliable based on PLN standards (standar PLN, SPLN) 68-2:1986. However, the CAIDI value of 1.813 hours/times/year indicated that the system response time was within acceptable limits. The availability of electricity, with an ASAI of 99.828% and an ASUI of 0.172%, was deemed satisfactory. Internal factors contributed to 10.47% disturbances. In contrast, external factors (weather and tree fall) accounted for 48.84%, and the remaining 40.69% were from unknown causes. Economic losses were calculated at Rp52,432.50/customer because these interruptions. More frequent maintenance and the implementation of additional protective measures are recommended to enhance reliability.

Copyrights © 2024






Journal Info

Abbrev

JNTETI

Publisher

Subject

Computer Science & IT Control & Systems Engineering Electrical & Electronics Engineering Energy Engineering

Description

Topics cover the fields of (but not limited to): 1. Information Technology: Software Engineering, Knowledge and Data Mining, Multimedia Technologies, Mobile Computing, Parallel/Distributed Computing, Artificial Intelligence, Computer Graphics, Virtual Reality 2. Power Systems: Power Generation, ...