Journal of Advanced Civil and Environmental Engineering
Vol 8, No 1 (2025): April

Pile Capacity Analysis Using Hydraulic Static Pile Driver and Pile Driver Analysis Test Method on the Tuntang River Bridge Foundation, Grobogan Regency

Al Mukarom, Su'udi (Unknown)
Rochim, Abdul (Unknown)
Astuti, Meilinda Dwi (Unknown)



Article Info

Publish Date
03 Jun 2025

Abstract

Abstract : Results of the analysis of the compressive pile capacity of the HSPD results with PDA-Test (CAPWAP) with The results of the pile capacity analysis using the PDA Test (CAPWAP) obtained an average value of Qult = 480 tons , while the results of the pile pressure capacity analysis using the HSPD Hydraulic Static Pile Driver obtained an average value of Qult = 250.17 Ton so that maximum load on a single pile with a load of Pmax = 225.78 tons / pile. Capacity analysis results from the interpretation value of the compressive pile capacity from the PDA-Test (CAPWAP) with HSPD Hydraulic Static Pile Driver Power support Pile Q ult = 392 Tons at a depth of 28 m from the top of the pile with a pile settlement value of 14.63 mm, so that pile able to support the maximum load on the pile and the settlement is still safe against Pmax settlement value 2.5 cm.

Copyrights © 2025






Journal Info

Abbrev

JACEE

Publisher

Subject

Civil Engineering, Building, Construction & Architecture Environmental Science

Description

Journal of Advanced Civil & Environmental Engineering invites and welcomes the submission of advanced research and review papers, innovations and developed selected conference papers that have never been previously publicized. This journal provides publications and a forum to the academics, scholars ...