Unesa Journal of Chemistry
Vol. 13 No. 3 (2024): Vol 13 No 3 (2024)

Optimasi Respon Elektrokimia Gliserol Berbagai Tingkat pH Studi Voltametri Siklik Dengan Elektroda Kerja Amalgam (Cu/Hg)

Rohman, Mohammad Chabibur (Unknown)
Pirim Setiarso (Unknown)



Article Info

Publish Date
22 Sep 2024

Abstract

Effect of pH on glycerol measurement using Cu/Hg amalgam working electrode by cyclic voltammetry method. The Cu/Hg amalgam electrode was chosen for its good conductivity and ease of surface cleaning, which prevents passivation due to compound buildup on the surface. In this study, the working electrode, comparison electrode, and auxiliary electrode were dipped into a glycerol solution with a pH variation between 5 and 8. The results show that the optimum pH for glycerol measurement is pH 7, with the highest reduction current response of -0.0142 A, indicating optimal glycerol ionization conditions. The decrease in current response above pH 7 is due to the interaction of glycerol with phosphate buffer which shifts the reaction equilibrium towards the formation of a by-product, hydroxypropenal. Therefore, the Cu/Hg amalgam electrode is effectively used as a working electrode for glycerol analysis, with the optimum pH at 7 for maximum results

Copyrights © 2024






Journal Info

Abbrev

unesa-journal-of-chemistry

Publisher

Subject

Biochemistry, Genetics & Molecular Biology Chemical Engineering, Chemistry & Bioengineering Chemistry Energy Materials Science & Nanotechnology

Description

UNESA Journal of Chemistry is online Journal covering all aspects of Chemistry. The journal publishes original research paper and review ...