Manual quality assessment of Platelet Concentrate (TC) is highly subjective and inconsistent, necessitating an objective, automated classification system. This study aims to develop a computationally efficient, low-cost model for TC quality classification using Histogram Features extracted from grayscale images combined with the K-Nearest Neighbor (KNN) algorithm. The methodology employed critical preprocessing steps, including StandardScaler for normalization and SMOTE for balancing the training data, followed by optimization across K=1 to K=30. The optimal model achieved a maximum accuracy of 69.23% at K=6, with an F1-Score of 71.43%, confirming robust performance on the imbalanced testing set. The results validate the effectiveness of the Histogram-KNN approach as a consistent and reliable decision support system for rapid TC quality screening in resource-limited settings.
Copyrights © 2025