Journal of Environmental and Development Studies
Vol. 7 No. 2 (2026): Journal of Environmental and Development Studies (In Press)

Experimental Study on the Effect of Zigzag Configuration of Paraffin Wax-Filled Aluminum Containers on the Thermal Performance of a Photovoltaic Thermal System

Sugito Julio Putra (Department of Mechanical Engineering, Faculty of Engineering, Universitas Widyatama, Bandung 40125, Indonesia)
Ayu Zahra Chandrasari (Department of Mechanical Engineering, Faculty of Engineering, Universitas Widyatama, Bandung 40125, Indonesia)
Ahmad Rajani (Research Center for Energy Conversion and Conservation, National Research and Innovation Agency (BRIN), Indonesia)



Article Info

Publish Date
01 Aug 2026

Abstract

The performance of photovoltaic (PV) panels decreases significantly as operating temperatures rise. To mitigate this, forced-air cooling is often employed, but fluctuating outdoor solar radiation makes the integration of phase change materials (PCM) essential for effective heat regulation. This study experimentally evaluates the thermal performance of an air-based photovoltaic thermal (PV/T) system integrated with a zigzag arrangement of aluminum containers filled with paraffin wax PCM. The zigzag geometry was specifically designed to extend the contact path for forced convective heat transfer. Three PCM mass variations (150 g, 200 g, and 250 g) were tested outdoors in an urban environment from 09:00 to 15:00 WIB. The system's thermal response was monitored using K-type thermocouples, DHT22 sensors, and a solar power meter to record radiation intensity, component temperatures, and inlet-outlet air temperature differences (ΔT). Experimental results showed average solar irradiance values of 817.16, 643.76, and 606.05 W/m² for the 150 g, 200 g, and 250 g tests, respectively. The PV backsheet recorded the highest average temperatures across all setups, reaching up to 57.88°C. Notably, the 200 g PCM configuration demonstrated the optimal thermal response, achieving the highest peak PCM ΔT of 10.98°C at 13:00. Furthermore, the system yielded average positive air ΔT values of 6.37°C, 5.00°C, and 4.83°C for the respective masses. These findings confirm that forced air flow effectively removes heat from the zigzag PCM section, highlighting that selecting an appropriate PCM mass is critical for balancing heat absorption and continuous convective removal under dynamic field conditions.

Copyrights © 2026






Journal Info

Abbrev

jeds

Publisher

Subject

Biochemistry, Genetics & Molecular Biology Chemical Engineering, Chemistry & Bioengineering Economics, Econometrics & Finance Environmental Science Social Sciences

Description

Aim of the Journal: The aims of this journal are to provide a place for graduate students, academicians, researchers, and practitioners to interchange and publish the original research or review articles related to the domain of environmental and development studies. Scope of the Journal: 1. ...