Journal of Applied Pharmaceutical Research
Vol. 14 No. 4 (2026)

Enhanced selectivity in alpelisib quantification in human plasma: a validated LC-MS/MS method with deuterated internal standard

Venkateswararao Agraharapu (School of Pharmaceutical Sciences and Technologies, Jawaharlal Nehru Technological University, Kakinada. Andhra Pradesh, Indi)
Venkata Rao Vutla (Department of Pharmaceutical Analysis, Chebrolu Hanumaiah Institute of Pharmaceutical Sciences, Chandramoulipuram, Chowdavaram, Andhra Pradesh, India.)
Vidyadhara Suryadevara (Department of Pharmaceutics, Chebrolu Hanumaiah Institute of Pharmaceutical Sciences, Chandramoulipuram, Chowdavarm, Guntur-522019, Andhra Pradesh, India)



Article Info

Publish Date
31 Jul 2026

Abstract

Background: To enhance efficacy and manage dose-limiting toxicities such as hyperglycemia, therapeutic drug monitoring of alpelisib (ALB), a phosphatidylinositol 3-kinase alpha (PI3Kα) inhibitor used in advanced breast cancer, is essential. This study aimed to develop and validate a selective, sensitive, and high-throughput liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the quantification of ALB in human plasma to support pharmacokinetic studies and therapeutic drug monitoring. Methodology: Alpelisib-D3 was used as a deuterated internal standard (IS). Analytes were extracted from 50 µL of plasma by liquid-liquid extraction using n-hexane and methyl tert-butyl ether (20:80, v/v). Chromatographic separation was performed on an X-Terra RP8 column using an isocratic mobile phase of 5 mM ammonium acetate buffer (pH 5.00) and acetonitrile (10:90, v/v) at 0.4 mL/min. Detection was carried out in positive electrospray ionization mode using multiple reaction monitoring of m/z 442.15→141.07 for ALB and m/z 445.36→144.05 for the IS. Validation included linearity, precision, accuracy, recovery, matrix effect, carryover, dilution integrity, and stability. Results and discussion: The method was linear over 50.0–10,000 ng/mL. Intra- and inter-day precision (CV%) was <4.2%, and accuracy ranged from 94.5% to 106.2%. Mean extraction recovery exceeded 90%, with no significant matrix effects. Carryover, stability, and dilution integrity also met acceptance criteria. Conclusion: A reliable, sensitive, and selective LC-MS/MS method was successfully developed and validated. The method is suitable for high-throughput pharmacokinetic studies and therapeutic drug monitoring of ALB in human plasma.

Copyrights © 2026






Journal Info

Abbrev

joapr

Publisher

Subject

Medicine & Pharmacology

Description

Journal of Applied Pharmaceutical Research (JOAPR) is an official publication of Creative Pharma Assent (CPA). It is an open access, peer review online international journal. JOAPR is primarily focused on multiple discipline of pharmaceutical sciences (Pharmaceutics, Pharmaceutical Technology, ...