Indonesian Journal of Chemistry
Vol 26, No 5 (2026)

Preliminary Evaluation of a Passive Sampler Based on Polymeric Inclusion Membranes (PIM) for Measurement of Filterable Reactive Phosphate (FRP) in Freshwater Systems

Dina de Jesus Branco (Department of Chemistry, Faculty of Science, Technology, and Mathematics, Universitas Brawijaya, Jl. Veteran, Malang 65145, Indonesia)
Barlah Rumhayati (Department of Chemistry, Faculty of Science, Technology, and Mathematics, Universitas Brawijaya, Jl. Veteran, Malang 65145, Indonesia)
Qonitah Fardiyah (Department of Chemistry, Faculty of Science, Technology, and Mathematics, Universitas Brawijaya, Jl. Veteran, Malang 65145, Indonesia)



Article Info

Publish Date
23 Sep 2026

Abstract

Monitoring filterable reactive phosphate (FRP) in aquatic systems is important for eutrophication control. This study evaluated a polymer inclusion membrane (PIM)-passive sampler for FRP measurement in freshwater. The PIM was fabricated by solvent casting using poly(vinyl chloride), Aliquat 336 chloride, and 1-decanol at a 70:20:10 (w/w) ratio and characterized for morphology, elemental distribution, functional groups, wettability, and mechanical properties. The PIM exhibited a smooth, dense, non-porous structure, moderate hydrophilicity, and good mechanical stability, all of which support its suitability for carrier-mediated FRP transport. Laboratory calibration using the kinetic approach gave an FRP permeability coefficient of (6.49 ± 3.39) × 10−7 m s−1 and a sampling rate of (6.15 ± 3.20) × 10−11 m3 s−1. In a preliminary evaluation using field-collected waters exposed under controlled laboratory conditions for 24 h, the sampler yielded time-weighted average FRP concentrations of (0.91 ± 0.05) × 10−5 mol L−1 in river water, (0.34 ± 0.02) × 10−5 mol L−1 in irrigation water, and (0.30 ± 0.01) × 10−5 mol L−1 in fishpond water. The sampler performed best in river water, where matrix interference was lowest. These results indicate that the PIM passive sampler is promising for preliminary operational FRP monitoring in freshwater, although matrix-specific calibration remains necessary.

Copyrights © 2026






Journal Info

Abbrev

ijc

Publisher

Subject

Chemical Engineering, Chemistry & Bioengineering Chemistry

Description

Indonesian Journal of Chemistry is an International, peer-reviewed, open access journal that publishes original research articles, review articles, as well as short communication in all areas of chemistry including applied chemistry. The journal is accredited by The Ministry of Research, Technology ...