RESWARA: Jurnal Riset Ilmu Teknik
Vol. 4 No. 4 (2026): RESWARA: Jurnal Riset Ilmu Teknik, October 2026

Rooftop Water-Tank Operational Mass Effect on Seismic Compliance of a 7-Story RC Special Moment Frame

Florindo da Costa Martins (Master'
s Program in Civil Engineering, Universitas Atma Jaya Yogyakarta, Yogyakarta, Indonesia)

Taufiqurrohman Taufiqurrohman (Master'
s Program in Civil Engineering, Universitas Atma Jaya Yogyakarta, Yogyakarta, Indonesia)

Sergio Gandhi Lourdes Belo (Master'
s Program in Civil Engineering, Universitas Atma Jaya Yogyakarta, Yogyakarta, Indonesia)

Cosme Soares Fraga (Geomatics Study Program, Universitas Gadjah Mada, Yogyakarta, Indonesia)



Article Info

Publish Date
02 Oct 2026

Abstract

Rooftop water tanks are near-universal in Indonesian multi-story buildings, yet the mass of stored water is frequently omitted from the seismic mass definition applied in structural design. Whether this omission is consequential depends on the seismic hazard of the site, and hazard across the Indonesian archipelago varies widely between regions. This study examines how the inclusion of rooftop operational water mass alters the code-compliance status of a fixed 7-story reinforced concrete Special Moment Resisting Frame (SMRF) when assessed at three locations of increasing hazard: Yogyakarta, Kupang, and Atambua. A three-dimensional model was constructed in ETABS Version 21 and subjected to modal response spectrum analysis in accordance with SNI 1726:2019, with output post-processed in MATLAB R2023b. Two operational states were compared: an empty tank (baseline) and a full 18,000 kg tank (governing condition). Design base shear increased by 13.8%, 14.6%, and 15.9% at Yogyakarta, Kupang, and Atambua, respectively. Maximum inter-story drift ratios rose from 1.65% to 1.95% at Yogyakarta, from 2.10% to 2.55% at Kupang, and from 2.40% to 2.85% at Atambua, against an allowable limit of 2.00%. The most consequential finding is that drift exceedances in Kupang and Atambua pre-exist the full-tank condition; operational mass enlarges an existing deficit rather than creating one. Operational mass acts as an aggravating factor in high-hazard zones. Furthermore, while element capacity checks were beyond the scope of this linear analysis, the systemic failure to satisfy drift limits indicates a fundamental stiffness deficiency, strongly suggesting that member proportioning transferred from moderate-hazard Java is inadequate for eastern Indonesia.

Copyrights © 2026






Journal Info

Abbrev

reswara

Publisher

Subject

Aerospace Engineering Automotive Engineering Chemical Engineering, Chemistry & Bioengineering Civil Engineering, Building, Construction & Architecture Control & Systems Engineering Electrical & Electronics Engineering Industrial & Manufacturing Engineering Mechanical Engineering Transportation

Description

RESWARA: Jurnal Riset Ilmu Teknik is a leading scholarly platform that examines the strategic role of engineering disciplines in advancing the Sustainable Development Goals (SDGs). The journal is dedicated to publishing recent research, innovations, and engineering solutions that support sustainable ...