Uji Recovery Alat Rayto RT-1904C terhadap Pemeriksaan Glukosa Metode GOD-PAP

Alfino Validita Sidiq (Jurusan Teknologi Laboratorium Medis, Poltekkes Kemenkes Pontianak, Pontianak, Indonesia| Poltekkes Kemenkes Pontianak)
Tiara Larashinta (Jurusan Teknologi Laboratorium Medis, Poltekkes Kemenkes Pontianak, Pontianak, Indonesia| Poltekkes Kemenkes Pontianak)
Gervacia J Ratnawati (Jurusan Teknologi Laboratorium Medis, Poltekkes Kemenkes Pontianak, Pontianak, Indonesia| Poltekkes Kemenkes Pontianak)
Ratih Indrawati (Jurusan Teknologi Laboratorium Medis, Poltekkes Kemenkes Pontianak, Pontianak, Indonesia| Poltekkes Kemenkes Pontianak)
Slamet Slamet (Jurusan Teknologi Laboratorium Medis, Poltekkes Kemenkes Pontianak, Pontianak, Indonesia| Poltekkes Kemenkes Pontianak)
Hendra B Sungkawa (Jurusan Teknologi Laboratorium Medis, Poltekkes Kemenkes Pontianak, Pontianak, Indonesia| Poltekkes Kemenkes Pontianak)



Article Info

Publish Date
25 Sep 2026

Abstract

Background: The accuracy of blood glucose testing is crucial in clinical diagnostics. A recovery test is a key validation parameter for evaluating the performance and reliability of an analytical instrument. This study aimed to evaluate the performance of the Rayto RT-1904C analyzer for glucose testing using the GOD-PAP method via a recovery test. Methods: This true experimental study used glucose standard samples spiked into normal and abnormal control serum at three concentrations (1%, 2%, 3%). Each concentration was measured with 9 replicates using the Rayto RT-1904C analyzer. The recovery percentage was calculated by comparing the measured value to the target value. Statistical analysis used the Mann-Whitney test. Results: The mean recovery percentages for normal control serum at 1%, 2%, and 3% concentrations were 95.81%, 98.59%, and 95.47%, respectively. For abnormal control serum, the mean values were 103.02%, 101.49%, and 97.70%. All values were within the acceptable range of 95-105%. Although the Mann-Whitney test showed a significant difference (p<0.05) between the two serum types, the instrument's performance is clinically acceptable. Conclusion: The Rayto RT-1904C analyzer demonstrated good accuracy and reliability for glucose testing with the GOD-PAP method, as evidenced by recovery values that met standard criteria.