Proceeding of International Conference Health, Science And Technology (ICOHETECH)
2026: Proceeding of the 7th International Conference Health, Science And Technology (ICOHETECH)

COMPARISON OF ACCURACY CELL GROUPING AND SERUM GROUPING EXAMINATION FOR ABO BLOOD TYPES BASED ON VARIATIONS IN CELL SUSPENSION CONCENTRATION

Annisa Rahmawati (Universitas Duta Bangsa Surakarta)
Fredericus Pramonodjati (Universitas Duta Bangsa Surakarta)
Erika Dwi Susanti (Universitas Duta Bangsa Surakarta)
Margaretha Alesandria Natasya Weka (Universitas Duta Bangsa Surakarta)



Article Info

Publish Date
26 Sep 2026

Abstract

ABO blood grouping relies on both cell grouping and serumgrouping to ensure diagnostic accuracy. Differences inagglutination intensity between these two methods acrossvarying cell suspension concentrations can impact testinterpretation. This study aimed to evaluate and comparethe agglutination grades between cell grouping and serumgrouping using Test Cell A and Test Cell B across differentconcentrations (3%, 5%, and 10%). An observationalcomparative study was conducted using ordinalagglutination score data. The non-parametric WilcoxonSigned-Rank test was utilized to determine significantdifferences between cell grouping and serum grouping foreach test cell type. Statistical analysis using the WilcoxonSigned-Rank test revealed no significant difference inagglutination scores between cell grouping and serumgrouping for Test Cell A and Test Cell B (p > 0,05). In TestCell A, a p-value of 0.750 was obtained, and in Test Cell B, ap-value of 0.625 was obtained. This indicates that bothmethods produce statistically comparable examinationresults across the concentrations of 3%, 5%, and 10%.

Copyrights © 2026