Lentera Perawat
Vol. 7 No. 4 (2026): October - December

Murottal versus white noise as nursing auditory interventions for immediate blood pressure changes in patients with acute myocardial infarction: A quasi-experimental study

Riski Amelia (Nursing Study Program, Sekolah Tinggi Ilmu Kesehatan Bina Husada, Palembang 30131, South Sumatra, Indonesia)
Aris Citra Wisuda (Nursing Profession Study Program, Sekolah Tinggi Ilmu Kesehatan Bina Husada, Palembang 30131, South Sumatra, Indonesia)
Rinda Suciarti (Nursing Study Program, Sekolah Tinggi Ilmu Kesehatan Bina Husada, Palembang 30131, South Sumatra, Indonesia)
Indra Frana Jaya Kk (Faculty of Midwifery and Nursing, Universitas Kader Bangsa, Palembang, South Sumatra, Indonesia)
Citra Suraya (Nursing Study Program, Sekolah Tinggi Ilmu Kesehatan Bina Husada, Palembang 30131, South Sumatra, Indonesia)
Romliyadi Romliyadi (Nursing Profession Study Program, Sekolah Tinggi Ilmu Kesehatan Bina Husada, Palembang 30131, South Sumatra, Indonesia)
Sutrisari Sabrina Nainggolan (Nursing Profession Study Program, Sekolah Tinggi Ilmu Kesehatan Bina Husada, Palembang 30131, South Sumatra, Indonesia)



Article Info

Publish Date
27 Oct 2026

Abstract

Background: In patients with acute myocardial infarction (AMI), pain, clinical uncertainty, and environmental stress may influence short-term hemodynamic measurements. Qur’anic murottal and white noise represent spiritually meaningful and content-neutral auditory approaches, respectively, but their immediate comparative responses remain uncertain. Objective: To compare pretest-to-posttest changes in systolic and diastolic blood pressure following Qur’anic murottal and white-noise interventions among hospitalized patients with AMI. Methods: This non-equivalent, two-group pretest–posttest quasi-experimental study included 52 consecutively recruited patients (26 per group) in a cardiovascular care unit in South Sumatra, Indonesia, in June 2026. Blood pressure was measured before and after the assigned intervention using a calibrated digital sphygmomanometer. Within-group mean reductions were assessed using paired t tests; between-group differences in mean reduction were assessed using independent t tests (two-sided α = 0.05). Allocation procedures and several intervention and measurement details were not recoverable from archived records. Results: Mean systolic reduction was 2.692 mmHg (95% confidence interval [CI] 1.878 to 3.506) with murottal and 1.846 mmHg (95% CI 1.213 to 2.479) with white noise. Mean diastolic reduction was 2.000 mmHg (95% CI 1.476 to 2.524) and 1.692 mmHg (95% CI 1.284 to 2.101), respectively. The murottal-minus-white-noise differences in reduction were 0.846 mmHg (95% CI −0.290 to 1.982; p = 0.141) for systolic and 0.308 mmHg (95% CI −0.340 to 0.956; p = 0.344) for diastolic pressure. Conclusion: Both groups exhibited small immediate reductions, without a statistically detected difference between interventions. Nonrandomized allocation, baseline diastolic imbalance, and unavailable treatment and measurement details preclude conclusions about independent efficacy, equivalence, or sustained blood-pressure control.

Copyrights © 2026






Journal Info

Abbrev

lenteraperawat

Publisher

Subject

Health Professions Nursing Public Health

Description

Lentera Perawat is intended to be the journal for publishing articles reporting the results of research on Health Science field especially Nursing and Midwifery, Public Health as well as with their development through interdisciplinary and multidisciplinary ...