This Author published in this journals
All Journal Lentera Perawat
Riski Amelia
Nursing Study Program, Sekolah Tinggi Ilmu Kesehatan Bina Husada, Palembang 30131, South Sumatra, Indonesia

Published : 1 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 1 Documents
Search

Murottal versus white noise as nursing auditory interventions for immediate blood pressure changes in patients with acute myocardial infarction: A quasi-experimental study Riski Amelia; Aris Citra Wisuda; Rinda Suciarti; Indra Frana Jaya Kk; Citra Suraya; Romliyadi Romliyadi; Sutrisari Sabrina Nainggolan
Lentera Perawat Vol. 7 No. 4 (2026): October - December
Publisher : School of Health Sciences Al-Ma'arif

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.52235/lp.v7i4.998

Abstract

Background: In patients with acute myocardial infarction (AMI), pain, clinical uncertainty, and environmental stress may influence short-term hemodynamic measurements. Qur’anic murottal and white noise represent spiritually meaningful and content-neutral auditory approaches, respectively, but their immediate comparative responses remain uncertain. Objective: To compare pretest-to-posttest changes in systolic and diastolic blood pressure following Qur’anic murottal and white-noise interventions among hospitalized patients with AMI. Methods: This non-equivalent, two-group pretest–posttest quasi-experimental study included 52 consecutively recruited patients (26 per group) in a cardiovascular care unit in South Sumatra, Indonesia, in June 2026. Blood pressure was measured before and after the assigned intervention using a calibrated digital sphygmomanometer. Within-group mean reductions were assessed using paired t tests; between-group differences in mean reduction were assessed using independent t tests (two-sided α = 0.05). Allocation procedures and several intervention and measurement details were not recoverable from archived records. Results: Mean systolic reduction was 2.692 mmHg (95% confidence interval [CI] 1.878 to 3.506) with murottal and 1.846 mmHg (95% CI 1.213 to 2.479) with white noise. Mean diastolic reduction was 2.000 mmHg (95% CI 1.476 to 2.524) and 1.692 mmHg (95% CI 1.284 to 2.101), respectively. The murottal-minus-white-noise differences in reduction were 0.846 mmHg (95% CI −0.290 to 1.982; p = 0.141) for systolic and 0.308 mmHg (95% CI −0.340 to 0.956; p = 0.344) for diastolic pressure. Conclusion: Both groups exhibited small immediate reductions, without a statistically detected difference between interventions. Nonrandomized allocation, baseline diastolic imbalance, and unavailable treatment and measurement details preclude conclusions about independent efficacy, equivalence, or sustained blood-pressure control.