Residential electrical installations are an important part of household infrastructure, but aging wiring, inadequate protection, grounding deficiencies, and excessive use of multiple-socket outlets can increase safety risks. This study develops a standard-based framework to assess residential electrical installations with reference to the Indonesian Ministry of Energy and Mineral Resources Regulation No. 10 of 2021 and PUIL 2011. A descriptive quantitative approach is applied through observation, interviews, documentation, and technical measurements of insulation resistance, grounding resistance, and protective-device trip time. The assessment uses three compliance levels—compliant, minor deviation, and critical deviation—and converts them into three feasibility categories: feasible, feasible with improvement, and not feasible. The draft demonstrates the method using research data from 15 residential houses. The research results show six feasible houses (40.0%), four houses feasible with improvement (26.7%), and five houses not feasible (33.3%). Grounding is the weakest parameter, with seven of fifteen houses meeting the ≤5 Ω criterion. The framework can support corrective-action priorities and electrical-fire mitigation.