Liquid waste generated from analytical activities using Atomic Absorption Spectrophotometry (AAS) contains heavy metals such as copper (Cu) and requires treatment before discharge into the environment. This study aimed to determine the effectiveness of a sequential combination of precipitation using NaOH, coagulation using Poly Aluminium Chloride (PAC), and adsorption using TiO₂ in reducing Cu concentrations in laboratory wastewater. The treatment was conducted in stages with variations in TiO₂ dosage (0.2, 0.4, 0.6, and 0.8 g) and contact time (30, 60, and 90 minutes). The initial Cu concentration was 17.32 mg/L with a pH of 1.19. After treatment using NaOH, PAC, and TiO₂ at a dosage of 0.4 g and a contact time of 90 minutes, the Cu concentration decreased to 0.5516 mg/L with an overall removal efficiency of 96.82%. During the process, the pH changed to 10.25 after NaOH addition, 6.58 after PAC addition, and ranged from 5.83 to 6.59 after TiO₂ addition. The results indicate that the combination of NaOH, PAC, and TiO₂ is effective in reducing Cu concentrations in laboratory wastewater from AAS analysis to levels below the quality standard.