Green hydrogen production using photovoltaic (PV)-powered electrolysis is challenged by intermittent irradiance, which changes the electrical operating point of the electrolyzer. This study investigates the maximum molar point (MMP) as a hydrogen-oriented operating concept for a PV–buck–proton exchange membrane (PEM) electrolyzer system. A dual-loop proportional–integral (PI) controller regulates the electrolyzer voltage and current, while the MMP is identified separately through duty-cycle characterization. The final model uses one 1Soltech 1STH-220-P PV module and a 50 kHz buck converter. A two-stage duty-cycle sweep identifies a near-maximum hydrogen-production region at D=0.75–0.85, with approximately 2.53710-5 mol/s at 1,000 W/m². Under irradiance levels from 600 to 1,000 W/m², MMP-oriented operation increases mean hydrogen production by 20.66–73.91% relative to conventional perturb-and-observe (P&O) maximum power point tracking (MPPT). The average hydrogen-production rate increases from 1.4386×10-5 mol/s for MPPT to 2.2458×10-5 mol/s for MMP-oriented operation, corresponding to an average improvement of 55.88%, while the average coefficient of variation (CV) decreases from 0.830% to 0.081%. The results demonstrate the potential of shifting the optimization objective from PV power toward hydrogen production; adaptive online MMP tracking, temperature/degradation effects, and parameter-robustness analysis remain future work.