Turbine Unit 05 at PT Bintan Alumina Indonesia is a 25 MW back-pressure steam turbine that supplies electricity and process steam for alumina production. This study evaluates its performance using 90 days of operating data collected from December 2025 to February 2026. Steam properties were calculated using SteamTab, and Actual Steam Rate (ASR), Theoretical Steam Rate (TSR), and internal efficiency were evaluated under two inlet-pressure conditions. Inlet pressure ranged from 8.46 to 8.90 MPa. The mean ASR was 9.306 kg/kWh, compared with the design value of 8.443 kg/kWh, while mean internal efficiency was 65.09%, compared with the design value of 78.67%. The high-pressure group had a mean ASR of 9.298 kg/kWh, only 0.014 kg/kWh (approximately 0.15%) lower than the 9.312 kg/kWh mean for the low-pressure group. Because inferential statistical testing was not available from the summary data, this difference is interpreted descriptively rather than as evidence of a statistically significant improvement. The main contribution is a unit-specific assessment that compares actual and ideal steam consumption with internal efficiency under the observed operating conditions and identifies performance gaps for follow-up monitoring.