PHARMACY: Jurnal Farmasi Indonesia (Pharmaceutical Journal of Indonesia)
Jurnal Pharmacy, Vol. 06 No. 03 Desember 2009

OPTIMASI METODE PENETAPAN RANITIDIN DALAM PLASMA MANUSIA SECARA IN VITRO DENGAN METODE SPEKTROFOTOMETRI ULTRAVIOLET-VISIBEL

Pri Iswati Utami (Unknown)
Wahyu Utaminingrum (Unknown)
Nur Aida Masyitoh (Unknown)



Article Info

Publish Date
31 Aug 2016

Abstract

ABSTRAK Telah dilakukan penelitian Optimasi Penetapan Ranitidin dalam Plasma Manusia secara in vitro dengan metode spektrofotometri Ultraviolet-Visibel. Penelitian ini bertujuan untuk menganalisis ranitidin dalam plasma manusia secara in vitro dengan metode spektrofotometri Ultraviolet-Visibeldan untuk memperoleh hasil metode analisis ranitidin dalam plasma manusia secara in vitro dengan metode spektrofotometri yang optimal. Metode untuk Optimasi Penetapan Ranitidin dalam Plasma Manusia secara in vitro dilakukan dengan metode spektrofotometri UV-VIS menggunakan pelarut HCl 0,1 N. Pada penelitian ini digunakan dua metode. Metode pertama larutan baku ranitidin ditambahkan di awal, sedangkan pada metode dua larutan baku ranitidin ditambahkan di akhir yaitu setelah TCA dan plasma dicampur, dan disentrifugasi. Dari metode dua diperoleh panjang gelombang maksimum sebesar 320,5 nm pada konsentrasi akhir ranitidin dalam plasma 500 ppm. Penentuan linieritas kurva kalibrasi menunjukkan hubungan yang linier antara konsentrasi dengan absorbansi pada rentang 200 sampai 600 ppm dengan koefisien korelasi (r) = 0,997, a = 0,081, dan b = 9,417x10¬¬ 4. Hasil uji ketelitian menggunakan metode 1 untuk 500 ppm (KV = 2,28%), sedangkan harga KV untuk konsentrasi 500 ppm dengan metode 2 adalah 1,60%. Batas deteksi= 43,64 ppm, batas kuantitasi = 145,48 ppm. Ketepatan dari rata-rata % Recovery 500 ppm = 104,99%. Metode kedua ini dapat diaplikasikan untuk uji bioavailabilitas dan bioekuivalensi ranitidin secara in vivo. Kata kunci : ranitidin; plasma manusia; optimasi metode; spektrofotometri ABSTRACT Research of determination ranitidine plasma concentration in vitro has been done. This research aimed to analysis ranitidine in human plasma in vitro with Ultraviolet-Visible spectrophotometry and to get result that optimal of analysis method in human plasma in vitro with Ultraviolet-Visible spectrophotometry. A method for determination ranitidine in human plasma in vitro used UV-VIS spectrophotometry with solvent HCl 0.1 N. This research was used two method. First method the ranitidine standard solution was added early, while the second method ranitidine standard solution was added after TCA and plasma had been mixed and sentrifugated. From second method has been gotten maximum wave length 320.5 nm in finish concentration ranitidine in human plasma 500 ppm. Determination of linearity calibration curve was linear between concentration with absorbantion range of 200-600 ppm with correlation efficient (r) = 0.997 a = 0.081 and b = 9.417x10-4. The result of precision with first method to 500 ppm (CV=2.28%), while CV value to 500 ppm with second method was 1.60%. Limit of detection was 43.64 ppm, limit of quantitation was 145.48%. The accuracy of recoveries 500 ppm was 104.99%. This second method was sufficiently applicable to bioavailability and bioequivalence studies of ranitidine in human plasma in vivo. Keywords : ranitidine; human plasma; method optimation; spectrophotometry.

Copyrights © 2009






Journal Info

Abbrev

PHARMACY

Publisher

Subject

Materials Science & Nanotechnology

Description

PHARMACY: Jurnal Farmasi Indonesia (Pharmaceutical Journal of Indonesia) is a scientific journal publishing original articles research in pharmaceutical science such as Pharmaceutical Technology, Pharmacology and Toxicology, Pharmaceutical Chemistry, Drug Discovery, Pharmacokinetics, Pharmaceutical ...