cover
Contact Name
Sadrina
Contact Email
sadrina@ar-raniry.ac.id
Phone
-
Journal Mail Official
-
Editorial Address
Syeikh Abul Rauf Kopelma Darussalam Banda Aceh, Indonesia, Postal Code 23111
Location
Kota banda aceh,
Aceh
INDONESIA
CIRCUIT: Jurnal Ilmiah Pendidikan Teknik Elektro
ISSN : 25493698     EISSN : 25493701     DOI : 10.22373
Journal Circuit is an Electrical Engineering Education Scientific journal which published by the Electrical Engineering Education Department, Faculty of Teaching and Training, Ar-Raniry State Islamic University, Banda Aceh. The Circuit Journal publishes empirical and theoretical contributions in the electrical engineering education scientific from the students, lecturers, professors or other scientists. The Circuit Journal manuscripts provide an original fundamental research, related to electrical engineering, electrical engineering education, and vocational education. The Circuit Journal also embossing the interpretative reviews, and discussion of new development in electrical engineering education
Arjuna Subject : -
Articles 11 Documents
Search results for , issue "Vol. 8 No. 1 (2024)" : 11 Documents clear
Design and Development of a Flood Detection Device for Drainage Systems Utilizing Float Switch Water Level Sensors Hais, Yosi Riduas; Saputra, Edi; Zk, Aldo Tri Ilham; Raboula, Andre
Circuit: Jurnal Ilmiah Pendidikan Teknik Elektro Vol. 8 No. 1 (2024)
Publisher : PTE FTK UIN Ar-Raniry

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22373/crc.v8i1.20974

Abstract

Indonesia ranks second in Asia Pacific in the list of the highest number of deaths due to natural disasters. In a year, more than 300 flood events occur, resulting in large losses, environmental damage and even loss of life. To overcome this problem, it is necessary to design a tool for monitoring water levels and rainfall. This research aims to design a flood detection system using the fuzzy method and using a float switch water level sensor. The results of the research show that this system can monitor water levels and rainfall using a web server. In the first test, it produces a fuzzy warning level in a safe condition. In the second test, the water level reached 51 cm with rainfall of 0.47 mm, and the fuzzy warning level was in a safe condition. Finally, in the third test, the average water level reached 99 cm with rainfall of 0.69 mm, resulting in a fuzzy warning level in an alert state. It can be concluded that this system needs to be improved in quality by adding items to the system.

Page 2 of 2 | Total Record : 11