cover
Contact Name
Abdul Wahib hasbullah
Contact Email
wahib.hasbullah@trunojoyo.ac.id
Phone
-
Journal Mail Official
haryanto.tmj@gmail.com
Editorial Address
-
Location
Kab. bangkalan,
Jawa timur
INDONESIA
Jurnal Teknik Elektro dan Komputer TRIAC
ISSN : 26157764     EISSN : 26155788     DOI : -
Jurnal Triac merupakan Jurnal Ilmiah di bawah naungan Program Studi Teknik Elektro, Fakultas Teknik Universitas Trunojoyo Madura. Jurnal TRIAC diterbitkan pertama kali pada bulan desember 2014, dan diterbitkan dua kali dalam setahun. Jurnal Triacs berisi artikel-artikel ilmiah yang meliputi bidang-bidang : Teknik Elektro, Multimedia, Mekatronika, Jaringan serta hasil Penelitian lainnya yang terkait dengan bidang-bidang tersebut.
Arjuna Subject : -
Articles 226 Documents
Evaluasi Dampak Kompresi dan Resolusi Citra terhadap Kinerja YOLOv11 pada Verifikasi Hunian Farendi Giotivano; Wiyli Yustanti; Ricky Eka
Jurnal Teknik Elektro dan Komputer TRIAC Vol 13, No 2 (2026): Oktober 2026
Publisher : Jurusan Teknik Elektro Universitas Trunojoyo Madura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21107/triac.v13i2.34940

Abstract

The implementation of computer vision in educational assistance verification systems is frequently hindered by high storage requirements and heavy server bandwidth consumption. Despite this, empirical research mapping the tolerance threshold of image degradation against object detection reliability in this domain remains limited. This study aims to evaluate the impact of JPEG compression and resolution reduction on the performance of the YOLOv11 model in identifying residential physical components, specifically roofs, walls, and floors. We conducted evaluations using various JPEG quality scenarios and image resolution adjustments. The experimental results demonstrate that YOLOv11 exhibits high robustness to compression. At a 75% quality level, file size was reduced by up to 70.6% while maintaining stable performance, achieving a precision of 0.7605, recall of 0.6651, mAP50 of 0.7341, and an inference time of 8.80 milliseconds. Regarding the resolution experiments, a 480-pixel dimension provided the most optimal outcome, yielding a precision of 0.7309, recall of 0.6711, mAP50 of 0.7333, and an inference time of 3.60 milliseconds. Conversely, extreme resolution reduction triggered a significant drop in accuracy. These findings confirm that the YOLOv11 architecture is more tolerant of compression quality than it is of resolution scaling. We recommend a 75% JPEG compression or a 480-pixel resolution as a standard operational baseline for efficient and accurate residential verification.
Implementasi Computer Vision YOLOv8s Untuk Counting Conveyor Berbasis Raspberry Pi 5 dan Akselerator Hailo-8L Mochammad Dimas Purwanto; Soraya Norma Mustika; Achmad Hamdan; Muladi Muladi; Paul Richard James Dixon
Jurnal Teknik Elektro dan Komputer TRIAC Vol 13, No 2 (2026): Oktober 2026
Publisher : Jurusan Teknik Elektro Universitas Trunojoyo Madura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21107/triac.v13i2.36213

Abstract

Industrial automation systems require automatic, real-time object counting on conveyors. Conventional sensors have limitations in handling variations in object shapes and conditions. A deep learning-based computer vision approach can be a solution, but its implementation on embedded devices such as the Raspberry Pi 5 faces computational limitations that result in slow inference speeds. This research implements the YOLOv8s model, accelerated using the Neural Processing Unit (NPU)-based Hailo-8L on the Raspberry Pi 5, for real-time object counting. A dataset of 1,343 bottle cap images was annotated using Roboflow and divided into 70% for training, 20% for validation, and 10% for testing, with a resolution of 640 x 640 pixels. The model was trained using Google Colab, exported to ONNX format, and compiled into Hailo Executable Format (.hef) using the Hailo Dataflow Compiler. Testing was conducted at conveyor speeds of 1.6–10.0 m/min with and without the Hailo-8L. Test results showed an increase in FPS from an average of 2.2 FPS to 28.9 FPS—approximately a 13.1-fold increase. In controlled counting tests, the system with Hailo-8L achieved up to 100% accuracy, while the system without Hailo-8L experienced a decline in counting accuracy at higher conveyor speeds. Validation in an industrial environment demonstrated a counting success rate of 97%. These results indicate that the Hailo-8L’s acceleration capability can reduce the YOLOv8s inference computational bottleneck and improve the real-time performance of the counting system.
Analysis of Loading and Phase Current Imbalance in Distribution Transformers at ULP Haurgeulis Sultan Agung; Jelita Permatasari
Jurnal Teknik Elektro dan Komputer TRIAC Vol 13, No 2 (2026): Oktober 2026
Publisher : Jurusan Teknik Elektro Universitas Trunojoyo Madura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21107/triac.v13i2.34290

Abstract

The ever-increasing demand for electrical energy necessitates that power distribution systems operate optimally in terms of both reliability and efficiency. Within these systems, distribution transformers play a crucial role in delivering electricity to customers. However, in actual field conditions, inter-phase load imbalances are frequently encountered, which can negatively impact transformer performance and the quality of electricity delivery. This issue prompted a study to analyze transformer loading levels and phase current imbalances during daytime load conditions in the service area of PT PLN (Persero) ULP Haurgeulis. The research involved direct observation, field measurements, and the processing of current and voltage data from five distribution substations. The parameters analyzed included phase currents, neutral current, transformer loading percentage, load imbalance, and power losses. The analysis revealed that the highest loading level occurred at the HRKC substation (52.64%), while the highest load imbalance was observed at the HRKI substation (65.12%). The HRKE substation exhibited the highest neutral current (49 A) and the greatest power losses (1,642.39 W). These results indicate significant load imbalances across several distribution substations; consequently, measures to balance inter-phase loads and implement periodic monitoring are required to enhance the efficiency and reliability of the power distribution system.
Digitalization of Automatic Monitoring and Control for Aquaculture Based on Internet of Things Tiara Hande Dias Kusumaningrum; Roytua Daud Siringoringo; Ilham Sayekti; Sri Kusumastuti
Jurnal Teknik Elektro dan Komputer TRIAC Vol 13, No 2 (2026): Oktober 2026
Publisher : Jurusan Teknik Elektro Universitas Trunojoyo Madura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21107/triac.v13i2.33342

Abstract

Fish pond management is highly dependent on water quality parameters such as temperature, pH level, and water level. In practice, monitoring and controlling these parameters are often performed manually, resulting in inefficiency and delayed response to environmental changes. This study presents the design and implementation of an Internet of Things-based monitoring and control system for fish pond maintenance. The system utilizes an ESP32 microcontroller integrated with a DS18B20 temperature sensor, a pH sensor, and an HC-SR04 ultrasonic sensor. The control method combines automatic and manual control. In automatic mode, the ESP32 activates the water pumps, aerator, and feeder based on predefined sensor thresholds, while in manual mode, control commands are issued through the Node-RED dashboard and transmitted to the ESP32 via the MQTT protocol. Experimental results show that the system achieved average percentage errors of 3.83% for temperature measurement, 2.56% for pH measurement, and 2.70% for water level measurement, while all actuators responded reliably to user commands through real-time communication. The developed system provides an effective and practical solution to improve efficiency and accessibility in aquaculture management.
Performance Evaluation of Active and Passive Scheduling Algorithms in IP Tunneling Load Balancing for DNS Traffic Salisa 'Asyarina Ramadhani; Luxfy Roya Azmi; Aulia Novira; Hazimah Widyagustin; Rendy Kurniawan
Jurnal Teknik Elektro dan Komputer TRIAC Vol 13, No 2 (2026): Oktober 2026
Publisher : Jurusan Teknik Elektro Universitas Trunojoyo Madura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21107/triac.v13i2.36170

Abstract

The exponential increase in global internet traffic frequently causes processing bottlenecks on Domain Name System (DNS) servers, degrading network Quality of Service (QoS). To address this, an IP Tunneling (LVS-TUN) load-balancing topology was implemented using Linux Virtual Server (IPVSADM) to evaluate 10 active and passive scheduling algorithms handling connectionless UDP traffic. Performance was assessed by simulating high-stress UDP flooding with 1,000 queries via DNSPerf across five iterations, extracting the average batch completion time and throughput, calculated from Wireshark packet traces, in Mbps. Under the tested single-client configuration, the Destination Hashing (DH) algorithm produced the lowest measured batch completion time of 1.0060 seconds and the highest calculated throughput of 1.7520 Mbps. However, this outcome is governed by the deterministic routing of the single-client test topology. Crucially, operational anomalies were identified in dynamic algorithms, specifically the Shortest Expected Delay (SED) and Never Queue (NQ) algorithms. Rather than distributing the load, rapid, connectionless UDP queries prompted IPVS to reuse active connection entries during the timeout window, thereby concentrating traffic on a single backend server.
Multivariate Time-Series Forecasting of Boiler Water Conductivity in Power Plant Using Machine Learning Ria Faulina
Jurnal Teknik Elektro dan Komputer TRIAC Vol 13, No 2 (2026): Oktober 2026
Publisher : Jurusan Teknik Elektro Universitas Trunojoyo Madura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21107/triac.v13i2.36504

Abstract

Water quality is a critical parameter for maintaining the reliable operation of power plants, particularly in the water–steam cycle and Heat Recovery Steam Generator (HRSG) systems. This study develops a predictive monitoring approach based on multivariate time-series forecasting to predict HP Drum Water conductivity using 35,064 hourly observations, of which 34,083 valid observations remained after preprocessing. Three models, namely Extreme Gradient Boosting (XGBoost), Long Short-Term Memory (LSTM), and Gated Recurrent Unit (GRU), were evaluated at forecasting horizons of 1, 6, and 24 h. The results show that XGBoost achieved the best performance at the 1-h horizon, with an RMSE of 3.3193, an MAE of 1.6358, and an R² of 0.9379. LSTM achieved the best performance at the 6-h and 24-h horizons, with R² values of 0.7256 and 0.5966, respectively. SHapley Additive exPlanations (SHAP) analysis identified current conductivity as the most influential feature. The predictive monitoring system also detected two early-warning events when conductivity exceeded the statistical threshold of approximately 44–45, demonstrating its potential to support predictive water-quality monitoring and earlier operational decision-making.