Journal of Electrical, Electronics and Informatics
Published by Universitas Udayana
ISSN : 25498304     EISSN : 26220393     DOI : -
Journal of Electrical, Electronics and Informatics is a peer-reviewed journal which devoted to the advancement and dissemination of scientific knowledge concerning electrical, electronics and informatics throughout the world for researchers and professionals. The journal is an official publication of the Institute for Research and Community Services Udayana University. The scope of these areas may encompass: (1) theory, methodology, practice, and applications; (2) analysis, design, development and evaluation; and (3) scientific and technical support to establishment of technical standards in the field of electrical, electronics and informatics.
Arjuna Subject : -
Articles 8 Documents
Search results for , issue "Vol 1 No 2 (2017): JEEI (September 2017)" : 8 Documents clear
Analysis Grounding System as Building Equipment Security Udayana University Denpasar I G. N. Janardana; W. Arta Wijaya; Cok Gede Indra Partha; N. Budiastra
Journal of Electrical, Electronics and Informatics Vol 1 No 2 (2017): JEEI (September 2017)
Publisher : Institute for Research and Community Services Udayana University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24843/JEEI.2017.v01.i02.p03

Abstract

Grounding system is one of the components in building equipment security. To fulfill the operational continuity of electronic equipment in Faculty of Engineering, Udayana University, Denpasar, a grounding system with a ground resistance of ? 3 ohms is required to be installed. The aim of this study is to find out the characteristics of grounding system to secure the equipment in the building around the research location, with ground resistance of ? 3 ohms and it is expected to be beneficial to use as a reference in grounding system installation as well as. According to the measurement results at the research location, it is found that the soil resistance value is equal to 0.23 ohms, where the soil resistivity (?) is 28.89 Ohm-meters. There are some results analysis obtained in ground resistance value of ? 3 Ohm. Those are 1) grounding system type 1 rod where minimal depth installation of the electrode is 14 meters with ground resistance value of 2.6751 ohms; 2) grounding system type two rod with s < L, it is obtained that each depth is 8 meters with distance of 2 meters between electrodes, where the ground resistance value is 2.4940 ohms. In the installation of two electrodes with s > L, it is gained that the depth of each electrode is 6 meters where the distance between the electrodes is 8 meters and the ground resistance value is 2.8718 ohms. By applying the plates type grounding system with 3 meters in length, 1 meter in width, and 2 meters in installation depth is gained 2.8431 ohms ground resistance value. Furthermore, by applying grid type grounding system with 2 meters in length h = 2,5 meters in depth, A = 4 meters in width and the total length of the electrode diameter 1 cm is 504 meters, it is obtained 2.0978 ohms ground resistance value.
Front Cover & TOC I Made Arsa Suyadnya
Journal of Electrical, Electronics and Informatics Vol 1 No 2 (2017): JEEI (September 2017)
Publisher : Institute for Research and Community Services Udayana University

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Operation of LED Light as Emergency Lighting Resource DC with Charger Control Based Arduino Uno ATmega I Wayan Rinas; I Made Suartika; Anak Agung Maharta Pemayun; I G. A. P. Raka Agung
Journal of Electrical, Electronics and Informatics Vol 1 No 2 (2017): JEEI (September 2017)
Publisher : Institute for Research and Community Services Udayana University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24843/JEEI.2017.v01.i02.p04

Abstract

Lighting is very important to support the activities of human life. To maintain the continuity of lighting can use power source from genset or battery. Now many manufactured LED (light emitting diode) bulb type which is energy saving with life time up to 50.000 hours. LEDs of this type can be operated with AC and DC current. The design control charger based Arduino Uno ATmega micro controller is used as a control system for charging and turning on LED lights. In this research the measurement of light intensity is done at 220 volt AC as reference, then measured the intensity of light for operation on some variation of DC voltage. The measurement results at DC voltage, LED Osram can be operated at 115 volt DC has reached the same light intensity with 220 volt AC. This selection aims to reduce the amount of battery usage as a DC power source.
Evaluation of Clipping and Filtering-Based PAPR Reduction in OFDM System N. M. A. E. D. Wirastuti; N. Pramaita; I M. A. Suyadnya; D. C. Khrisne
Journal of Electrical, Electronics and Informatics Vol 1 No 2 (2017): JEEI (September 2017)
Publisher : Institute for Research and Community Services Udayana University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24843/JEEI.2017.v01.i02.p05

Abstract

This paper investigates clipping and filtering techniques in reducing peak average power ratio (PAPR) of Orthogonal Frequency Division Multiplexing (OFDM) system. The concept of OFDM is to split a high speed serial data into parallel data at a lower speed, then the parallel data carried by mutually orthogonal subcarriers. The high of PAPR is one of disadvantages of OFDM system. The high PAPR can damages the form of OFDM and reduces its performance. The purpose of this study is to reduce PAPR using simulation. OFDM was simulated with and without clipping filtering then compared. The methods used to reduce PAPR was clipping and filtering technique. Clipping and filtering technique operates by clipping the output of inverse Fourier transform that exceed the threshold. Graphics PAPR vs. CCDF was used to evaluate the performance of OFDM systems. PAPR for OFDM system using Fourier transform when CCDF = 10-3 is 11,2 dB, with classical clipping PAPR was 4,1 dB and PAPR 4,6 dB when with deep clipping.
Graphic Monitoring on Test of Rocket Launch Payload I N. Budiastra; C. G. I. Partha; I G. N. Janardana; I W. A. Wijaya
Journal of Electrical, Electronics and Informatics Vol 1 No 2 (2017): JEEI (September 2017)
Publisher : Institute for Research and Community Services Udayana University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24843/JEEI.2017.v01.i02.p01

Abstract

Aviation technology and space is one of the leading technology for developed countries, especially in the form of rocket technology and charge. The countries that are capable of mastering these technologies will be respected by countries all over the world. Indonesia as the island nation with large and extensive maritime should have independence in the mastery of the technology of the rocket and payload. Therefore, continuous efforts are required to achieve independence, including through enhancing the sense of love of aviation technology and space technology, particularly at early stages the rocket and payload. Graphic Monitoring Test Rocket Launch Payload Attitude is the attitude of remote monitoring launch vehicle through the computer screen (display) continuously (real-time) data obtained from sensors-sensors that are mounted on the rocket's payload. 3D point (x, y, z) must be expressed as a graph visualization perspective drawings of rockets with the appropriate direction. The radar conducted computer GS (Ground Segment) or Ground Control Station (GCS. The result of the attitude of the Rocket Test launch Payloads have been able to communicate with the 3D data sending (x, y, and z) in real-time to the Ground segment. Wireless communication uses radio telemetry frequency 433 MHz, power of 100 mW, the distance range obtained in this study a maximum of 500 Meters in the air, without a hitch.
Study of The Electric Field Between Horizontal and Vertical Configuration Pole under 150 KV High Voltage Transmission Line (SUTT 150 KV) Anak Agung Ngurah Amrita
Journal of Electrical, Electronics and Informatics Vol 1 No 2 (2017): JEEI (September 2017)
Publisher : Institute for Research and Community Services Udayana University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24843/JEEI.2017.v01.i02.p06

Abstract

Distribution of electrical energy from a plant to a substation or from a substation to other substations usually uses a transmission line. In Bali, type of transmission line that is usually implemented is SUTT 150 kV. The magnitude of the applied voltage is an attempt to reduce power loss for long distance distribution. However, distributing electrical energy with increasing stress affects the increase of electric field around the transmission line. The negative impact of electricity distribution has been an environmental problem for PT. PLN (Persero), especially where there is conversion from an open area to be a residential. This problem has been the main reason for conducting this research. IRPA / INIRC recommendation states that exposure time is not limited to the electric field effect in work environment and public area including a residential area at frequency of 50/60 Hz is 5 kV/m. This recommendation is in accordance with SNI 04-6950-2003, on Threshold Limit Values ??Electric Field under SUTT and high-voltage wires. The first problem of this research is how large the intensity of the electric field between two poles of SUTT 150 kV with vertical and horizontal constructions which are built side by side? The second problem is what the characteristic of the electric field intensity between the two poles which are built side by side? From the analysis, it can be seen that the intensity of the electric field that occurs between the conductor of the vertical and horizontal pole configurations are still below the IRPA/INIRC and SNI 04-6950-2003 recommendation i.e. 1 up to 1.5 kV/m and at a distance of 18 meters to 25 meters there is an interaction of electric field intensity that occurs at these two configurations.
Performance Evaluation of CDMA - MIMO (STBC) System over Rayleigh Fading Channel for Image Transmission I G. A. K. Diafari Djuni H; I G. A. P. Raka Agung
Journal of Electrical, Electronics and Informatics Vol 1 No 2 (2017): JEEI (September 2017)
Publisher : Institute for Research and Community Services Udayana University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24843/JEEI.2017.v01.i02.p02

Abstract

Data transmission via wireless communication system is not only in text form but it also can be in image form. In the process of sending data or information, it often experiences interference in transmission media, which is fading. The method used in this research is by simulation using MATLAB. The simulation of CDMA-MIMO (STBC) system with Walsh spreading code is expected to reduce the disturbance of fading. Fading channels can be modeled using Rayleigh distribution. The number of users and spreading factors affect the performance of CDMA-MIMO (STBC) systems. The parameters used in this simulation were SNR, BER, and PSNR. The results showed that image reconstruction passing CDMAMIMO system with spreading factor 4 has better image quality. Its PSNR 33.9589dB when SNR -10dB. SNR was increased 10 dB then PSNR 60.00 dB. The increasing of spreading factor to 8 and 16 was obtained by increasing PSNR, PSNR 35.0685 dB and PSNR 37.5665 dB, respectively. For 4 users with Spreading Factor 4 and SNR 0 to 5 dB, it was changed the BER. This is influenced by changes in SNR. The higher SNR value, the average value of BER will be smaller. A growing number of users from 1 to 4 users were decreased the performance of the MIMO CDMA system when observed from the BER and PSNR.
Geographic Information System of Potential Tsunami Impact Areas and Safe Gathering Places for Coastal Tourism Area in Badung Regency, Bali Province I Made Arsa Suyadnya; Duman Care Khrisne
Journal of Electrical, Electronics and Informatics Vol 1 No 2 (2017): JEEI (September 2017)
Publisher : Institute for Research and Community Services Udayana University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24843/JEEI.2017.v01.i02.p07

Abstract

The Southern part of Bali especially Badung regency, in addition to having natural beauty and popular tourist attraction, it has a high potential for disaster. The fact is the coastline of Bali in the south is prone to tsunami because Bali is located close to the colliding zone between the Indo-Australian plate and the Eurasia plate, which presents the main source of the local tsunami that could hit the island of Bali. This research undertakes the design and development of a Geographic Information System (GIS) that can provide information and socialization of potential tsunami impact areas and safe gathering places for coastal tourism area in Badung regency. This application is built web-based by using Google Maps API v3. In this Geographic Information System, users can identify potential tsunami impact areas, obtain information on evacuation methods in the event of a tsunami disaster and can find the nearest safe gathering places to do an evacuation. By utilizing geolocation and direction services from Google Maps API v3, simulation of the nearest evacuation route has been successfully built. Evacuation is done by considering two possible evacuation sites. The first possibility is to evacuate to the nearest vertical high building, and the second evacuation site is away from the danger zone (red zone) and towards the safe zone (yellow zone or outside the yellow zone).

Page 1 of 1 | Total Record : 8