Journal of Robotics and Control (JRC) is an international open-access journal published by Universitas Muhammadiyah Yogyakarta. The journal invites students, researchers, and engineers to contribute to the development of theoretical and practice-oriented theories of Robotics and Control. Its scope includes (but not limited) to the following: Manipulator Robot, Mobile Robot, Flying Robot, Autonomous Robot, Automation Control, Programmable Logic Controller (PLC), SCADA, DCS, Wonderware, Industrial Robot, Robot Controller, Classical Control, Modern Control, Feedback Control, PID Controller, Fuzzy Logic Controller, State Feedback Controller, Neural Network Control, Linear Control, Optimal Control, Nonlinear Control, Robust Control, Adaptive Control, Geometry Control, Visual Control, Tracking Control, Artificial Intelligence, Power Electronic Control System, Grid Control, DC-DC Converter Control, Embedded Intelligence, Network Control System, Automatic Control and etc.
Articles 12 Documents
Search results for , issue "Vol 1, No 5 (2020): September" : 12 Documents clear
Path Loss Propagation Evaluation and Modelling based ECC-Model in Lowland Area on 1800 MHz Frequency Bengawan Alfaresi; Taufik Barlian; Feby Ardianto; Muhammad Hurairah
Journal of Robotics and Control (JRC) Vol 1, No 5 (2020): September
Publisher : Universitas Muhammadiyah Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.18196/jrc.1534

Abstract

Propagation modeling is the most important part of mobile wireless network planning. Wireless network planning requires an accurate calculation of the path, which depends on different environmental conditions. It requires accurate path loss modeling of the characteristics of a specific region. The study aimed to obtain a path loss propagation model by modifying the ECC model and using linear, logarithmic regression in lowland areas. The measurement used drive test method, located in the Jakabaring area that represented the lowland area. This research used four existing path loss models, namely Okumura-Hatta, COST-Hatta, Ericsson Model, and ECC Model. It was found that the Okumura-Hatta model had the largest RMSE value, 34.90, followed by the Ericsson model, 27.07, while the ECC model had the smallest RMSE value, 8.43. The ECC model required to be modified using logarithmic, linear regression to obtain the proposed model. The results of the evaluation showed that the proposed model improved with RMSE 4.93, MAPE 2.71, and MAD 3.91, whereas the values of the existing ECC Model before modification were 8.43 for RMSE, 4.72 for MAPE and 7.09 for MAD. The proposed model provided an accurate prediction of the path loss propagation in a lowland environment. The results of the study can be used for planning engineers to plan, design, and implement the wireless communication networks in lowland area conditions.
The Design of Digital Heart Rate Meter Using Microcontroller Tatiya Padang Tunggal; Shela Asta Juliani; Hendro Agus Widodo; Rachmad Andri Atmoko; Phong Thanh Nguyen
Journal of Robotics and Control (JRC) Vol 1, No 5 (2020): September
Publisher : Universitas Muhammadiyah Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.18196/jrc.1529

Abstract

Cardiac tests generally use an electrocardiograph, the results of which are used by medical teams to diagnose heart conditions. Individual ECG examination is held in a health care institution so that it cannot be held independently, considering the high costs and the need for analysis by a specialist.  It is, therefore, necessary to have a functional and portable device to detect heart rate. The heart rate measuring device, equipped with a finger sensor, was designed for adults. The 15-second measurement interval showed the heart rate in one minute and the results were shown on an LCD. The minimum system circuit used ATMega 16.